Download Print this page

Emerson Rosemount Wireless ET410 Quick Start Manual page 20

Corrosion transmitter
Hide thumbs Also See for Rosemount Wireless ET410:

Advertisement

Quick Start Guide
Figure 3-5: Alignment examples
NOTICE
When the worm-screws are tightened, the springs in the
tensioner are compressed. To avoid the strap becoming lose
or over-tightened when the pipe temperature changes, it is
important that the spring is set to the correct tension. Do not
over-tighten the worm-screws.
7. Ensure the metal plate is centered through the plus (+) shaped
cut-outs on both sides of the tensioner. If it is not centered,
either loosen or tighten the worm-screws on either side until
they do align. Ensure the sensor is firmly fixed and sitting
perpendicular to the pipe as shown in
8. When all the adjustments have been completed, make a final
check of the waveform quality (refer to
20
A. Correct tension – Plate is aligned with the wide part of the
cut-out.
B. Incorrect alignment – Plate above the wide part of the cut
out, tighten strap.
C. Incorrect alignment – Plate below the wide part of the cut
out, loosen strap.