  Connecting Multiple Inverters through RS485
 3. In the Follower inverter, connect the cable to the 2nd Inv RS485 connector.
 4. In the Leader inverter, connect the cable to either the 2nd Inv RS485 connector or
the SMRT EV RS485 connector.
 5. Pull the cables lightly to make sure they are properly connected.
 6. Close the communication glands of 5.5 N*m.
To connect an additional HD-Wave inverter:
 1. In the HD-Wave inverter, connect one end of the communication cable to the
RS485-1 connector on the communication board. For more information, refer to the
HD-Wave inverter Installation Guide .
 2. Pass the other end of the communication through Communication Gland 2 of the
Energy Hub inverter.
 3. Connect the cable to the 2nd Inv RS485 connector on the communication board.
 4. Pull the cables lightly to make sure they are properly connected.
 5. Close the communication glands of 5.5 N*m.
Figure 17: Connecting two Energy Hub inverters