SolarEdge Energy Bank Installation Manual page 59

Home hub inverter single phase for australia
Hide thumbs Also See for Energy Bank:
Table of Contents

Advertisement

58
  Creating an Ethernet (LAN) Connection
RJ45 Pin #
1
White/Orange
2
Orange
3
White/Green
4
Blue
5
White/Blue
6
Green
7
White/Brown
8
Brown
 7. Use a pre-crimped cable to connect via Communication Gland 1 to the RJ45 plug on
the inverter's communication board or, if using a spool of cable, connect as follows:
 a. Insert the cable through the gland.
 b. Remove the cable's external insulation using a crimping tool or cable cutter and
expose eight wires.
 c. Insert the eight wires into an RJ45 connector (see Figure 19 ).
 d. Use a crimping tool to crimp the connector.
 e. Connect the Ethernet connector to the RJ45 port on the communication board
(see Figure 18 ).
 8. For the switch/router side, use a pre-crimped cable or use a crimper to prepare an
RJ45 communication connector: Insert the eight wires into the RJ45 connector in the
same order as above .
 9. Connect the cable RJ45 connector to the RJ45 port of the Ethernet switch or router.
You can connect more than one inverter to the same switch/router or to different
switches/routers, as needed. Each inverter sends its monitored data independently
to the SolarEdge monitoring platform.
(1)
The inverter connection does not support RX/TX polarity change. Supporting crossover Ethernet cables
depends on the switch capabilities.
(1)
Wire Color
T568B
White/Green
White/Orange
White/Brown
Figure 19: Standard cable wiring
SolarEdge Home Hub Inverter Single Phase MAN-01-00812-1.5
T568A
Green
Blue
White/Blue
Orange
Brown
10Base-T Signal
100Base-TX Signal
Transmit+
Transmit-
Receive+
Reserved
Reserved
Received-
Reserved
Reserved