Figure 9.13: Room transform & matching dialog
Deselect any previously assigned Measurement Tool References prior
to matching of the coordinate systems. Otherwise matching results
will be erroneous.
Procedure A three-step process has to be performed:
1. Add measurement data from the reference coordinate system
tering the coordinates into the table
mum of three (3) data points is necessary for calculations.
The current set of reference points can be saved by pressing Save.
Delete single data points by selecting the corresponding row and press Remove.
Alternatively load the coordinates from a text file (ASCII) using the button Load. The
text file must comply to the following format:
The import strictly follows the sequence from the ASCII text file. Still in some cases
the data might be ambigous regarding its 3-D orientation. Toggle the tickbox
serve order of points
2. Select a calibrated and tracked Measurement Tool from the drop-down menu and
measure all points (e.g. on the corresponding object) which directly relate to the
reference points (e.g. from a CAD model) defined in step 1.
Each measurement can be started by:
reference points
to lock the order in the table