3.2.7

Configuration of default value

If users click the "Defaults" button, all of the module communication
parameters on the I-7530A-MR-FD will be set to the factory default, which
are:
Communication Mode = Normal
RS232/485/422:
CAN bus:
Pair-connection:
Modbus Slave:
I-7530A-MR-FD Modbus RTU to CAN Converter User's Manual (Version 1.0, 08/2022) ------------- 32
Baud rate
Data Bit
Stop Bit
Parity
Add Checksum
Error Response
Timestamp Response = No
CAN Specification = 2.0A
CAN bus Baud rate = 125 kbps
Enable CAN Filter = unchecked
Enable CAN FD = unchecked
End of Command
Fixed Tx CAN ID
Response with CAN ID = unchecked
Device ID
Specify CAN ID Table = empty
= 115200 kbps
= 8
= 1
= None
= No
= No
= None
= checked
= 1