Supermicro X13DSF-A User Manual page 64

Table of Contents

Advertisement

Super X13DSF-A User's Manual
Power On and BMC/BIOS Status LED Button
The Power On and BMC/BIOS Status LED button is located on Pin 1 of the front control panel
header located at JFP1. Momentarily contacting Pin 1 of JFP1 will power on/off the system
or display BMC/BIOS status. Refer to the table below for more information.
Green: solid on
BMC/BIOS blinking green at 4Hz
BIOS blinking green at 4Hz
BMC blinking red x2 (2 blinks red) at 4Hz, 1 pause at 2Hz (on-on-off-off)
BMC/BIOS blinking green at 1Hz
Front UID Switch/Reset Button
The Front UID switch/BMC Reset button/System Reset button connection is located on Pin 2
of JFP1, which is used in conjunction with the Reset button/UID switch select jumper located
at JRU1. To configure Pin 2 of JFP1 for front UID switch and BMC reset use in a chassis
that supports front UID connection, close Pin 1 and Pin 2 of JRU1. To set Pin 2 of JFP1 for
system reset support, close Pin 2 and Pin 3 of JRU1. Please refer to Section 2.9
for more information on JRU1
location of JRU1.
JFP1
1
1
Power Button
2
2
Reset/UID Button
3
UID LED_N
4
Fail LED_N (OH/FF/PF)
5
LAN-2 Activity LED
6
LAN-1 Activity LED (Aggregate all LAN)
7
HDD Acitivity LED
8
Standby LED_N
Power/RoT LED_N
9
10
P3V3_STBY
11
Ground
12
I2C Data
13
I2C Clock
14
Ground
Power Fail LED_P
15
16
P5V
P5V
17
18
P5V
19
Power Fail LED_N
20
Ground
Power Button
BMC/BIOS Status LED Indicator
Status
(page
81). Also see the motherboard layout below for the
Front UID Switch/Reset Button Select Jumper (JRU1)
State
Close Pin 1 and Pin 2 of JRU1
Close Pin 2 and Pin 3 of JRU1
1. Power On and BMC/BIOS Status LED Button
2. Reset Button/UID Switch Connection
3. JRU1 Jumper (Reset Button/UID Switch Select)
P1-AIOM PCIe 5.0x16 (J139)
SATA 0~3 (JS1)
JPW3
JRK1
PSU1
JPW2
CPU1
P1_NVME0/1
P1_NVME2/3
P1_NVME4/5
P1_NVME6/7
FAN8
FAN7
FAN6
64
Event
System power on
BMC/BIOS checking
BIOS recovery/update in progress
BMC recovery/update in progress
Flash not detected or golden image
checking failure
Jumper Settings
Description
Pin 2 of JFP1: used for front UID switch and
BMC reset support (Default)
Pin 2 of JFP1: used for system reset support
P2-AIOM PCIe 5.0 x16 (J7)
JTPM1
M.2-H2
M.2-H1
JSB1
JNCSI1
BMC
JL1
JIPMB1
PCH
LEDBMC
USB2/3 (3.0)
MT1_1
MT1_2
JBT1
PSU2
CPLD
BIOS LICENSE
MT2_1
MT2_2
X13DSF-A
MAC CODE
REV:1.01
BAR CODE
DESIGNED IN USA
MAC CODE
CPU2
P2_NVME0/1
P1_NVME10/11
BT1
P1_NVME8/9
P2_NVME2/3
P2_NVME4/5 P2_NVME6/7
FAN5
FAN4
FAN3
FAN2
(page
79)
JPW1
JFP1
LEDPWR
3
JRU1
FAN1
P2_NVME8/9
P2_NVME10/11

Advertisement

Table of Contents
loading

Table of Contents