Front Control Panel LEDs
Event
Power On
Solid On
HDD Activity
NIC Activity
Overheat
Fan Fail
Power Fail
Local UID On
Remote UID On
Checking
BMC/BIOS Blinking
at 4Hz
Recovering/Updating
BMC Blinking at 4Hz
BMC 2 Blinks at 4Hz,
1 Pause at 2Hz
(on-on-off-off)
Flash Not Detected or
BMC/BIOS Blinking
Golden Image Check Failed
at 1Hz
CPLD Recovery Mode
When Used as a UID LED Switch
Work with Rear UID LED (LED1) &
Front UID LED (JFP1: Pin 3 & Pin 4)
LED solid on: Unit identified;
Press JUIDB1 to turn on and off both rear and front UID
LED indicators
LED blink at 1Hz: Remote activated
LED blink at 10Hz: BIOS/BMC FW update
Front Control Panel (JFP1)
LED Indicators
Power
HDD
Blinking
Blinking
UID/BMC Reset Switch (JUIDB1)
Features & Settings
When Used as a BMC Reset Switch
Work with Rear UID LED (LED1) &
Front UID LED (JFP1: Pin 3 & Pin 4)
LED blinking: BMC reset
BMC Reset Type 1
BMC Reset Type 2
63
Chapter 2: Installation
LAN
UID
Information
Solid On
Blinking at 1Hz
Blinking at 1/4Hz
Solid On
Blinking at 1Hz
BIOS/BMC
Blinking at 10Hz
Blinking at 10Hz
Blinking at 10Hz
(MB UID LED)
(FP Red LED)
Triggering a (BMC) cold reboot;
LED: Starts blinking at 2Hz while
pressing and holding JUIDB1 for
more than six seconds;
Reset duration: 250ms
Triggering a (BMC) reset to factory
default configuration;
LED: Starts blinking at 4Hz while
pressing and holding JUIDB1 for
more than 12 seconds
Power Fail
Solid On