EDITION 12/ 2008
OPERATING MANUAL
2.4

SAFETY-RELEVANT INFORMATION ABOUT DISCHARGES

The plastic parts of the spray gun are charged electrostatically by the high-voltage field
of the spray pistol. Harmless discharges (brush discharges) are possible after contact with
plastic parts. They are completely harmless for people.
The corona discharge at the electrode end is visible during darkness at a distance of be-
tween 4 and 10 mm; 0.15 and 0.4 inches, between the spray gun and spray object.
2.5

USE IN AN EXPLOSION HAZARD AREA

2.5.1

CORRECT USE

The electrostatic spray guns GA 2000EAC and GA 2005EAC are suitable for spraying liquid
materials, particularly coating materials, using the air atomizing method.
Coating materials containing solvents of Explosion Class IIA may be used. The spray gun
may only be used in combination with a control unit EPG 3000.
2.5.2

EXPLOSION PROTECTION IDENTIFICATION

2.5.3

MAXI. SURFACE TEMPERATURE

PART NO. 350741
GA 2000EAC, GA 2005EAC