Trove2AG2/Trove2AM2 and Trove3AM3 accommodates AMAG boards with or without Altronix power supplies and sub-assemblies for
access systems.
Trove2AG2 - Trove2 enclosure with TAG2 Altronix/AMAG M4000 backplane
Trove2AG2 accommodates a combination of the following:
• Altronix Modules:
- Up to two (2) eFlow4NB, eFlow6NB, eFlow102NB, eFlow104NB or PoE201.
- One (1) NetWaySP4B.
- Up to three (3) LINQ8PD/ LINQ8PDCB, ACM8/ACM8CB, ACMS8/ACMS8CB, ACM4/ACM4CB, MOM5, PD4UL/PD4ULCB,
PD8UL/PD8ULCB, PDS8/PDS8CB, or VR6.
• AMAG Modules:
- Up to three (3) M4000 modules.
• Includes: tamper switch, cam lock, lock nuts, and mounting hardware.
• 16 Gauge enclosure with ample knockouts for convenient access.
Enclosure Dimensions (H x W x D): 27.25" x 21.75" x 6.5" (692.15mm x 552.5mm x 165.1mm).
TAG2 - Altronix/AMAG M4000 backplane only
• Includes mounting hardware.
Dimensions (H x W x D): 25.375" x 19.375" x 0.3125" (644.5mm x 482.6mm x 7.9mm).
Trove2AM2 - Trove2 enclosure with TAM2 Altronix/AMAG M2150 backplane
Trove2AM2 accommodates a combination of the following:
• Altronix Modules:
- Up to two (2) eFlow4NB, eFlow6NB, eFlow102NB, eFlow104NB or PoE201.
- Up to two (2) LINQ8PD/ LINQ8PDCB, ACM8/ACM8CB, ACMS8/ACMS8CB, ACM4/ACM4CB, MOM5, PD4UL/PD4ULCB,
PD8UL/PD8ULCB, PDS8/PDS8CB, or VR6.
• AMAG Modules:
- One (1) M2150-2DBC, M2150-4DBC or M2150-8DBC modules.
- One (1) M2150-2DC, M2150-4DC or M2150-AC244 modules.
• Includes: tamper switch, cam lock, lock nuts and mounting hardware.
• 16 Gauge enclosure with ample knockouts for convenient access.
Enclosure Dimensions (H x W x D): 27.25" x 21.75" x 6.5" (692.2mm x 552.5mm x 165.1mm).
TAM2 - Altronix/AMAG M2150 backplane
• 16 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D): 25.375" x 19.375" x 0.3125" (644.6mm x 492.1mm x 7.9mm).
Trove3AM3 - Trove3 enclosure with TAM3 Altronix/AMAG M2150 / M4000 backplane
Trove3AM3 accommodates a combination of the following:
• Altronix Modules:
- Up to two (2) eFlow4NB, eFlow6NB, eFlow102NB, eFlow104NB or PoE201.
- Up to two (2) ACM8/ACM8CB, ACMS8/ACMS8CB.
- Up to four (4) LINQ8PD/ LINQ8PDCB, ACM4/ACM4CB, MOM5, PD4UL/PD4ULCB, PD8UL/PD8ULCB, PDS8/PDS8CB, VR6.
• AMAG Modules:
- Up to two (2) M2150-4DC or M2150-AC244, M2150-DBU M2150-4DBC or M2150-8DBC modules.
- Up to four (4) M4000 modules.
• Includes: tamper switch, cam lock, lock nuts and mounting hardware.
• 16 Gauge enclosure with ample knockouts for convenient access.
Enclosure Dimensions (H x W x D): 36.12" x 30.12" x 7.06" (917.5mm x 768.1mm x 179.3mm).
TAM3 - Altronix/AMAG M2150 / M4000 backplane
• 16 Gauge backplane.
• Includes mounting hardware.
Dimensions (H x W x D): 34.0" x 28.0" x 0.3125" (863.6mm x 711.2mm x 7.9mm).
• UL 294 - 6th edition: Line Security I, Destructive Attack I, Endurance IV, Stand-by Power II*.
* Stand-by Power Level I if no battery is supplied.
• This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada.
• CE European Conformity.
- 2 -
Overview:
Specifications:
Agency Listings:
Trove2AG2 / Trove2AM2 / Trove3AM3
Need help?
Do you have a question about the Trove2AG2 and is the answer not in the manual?
Questions and answers