Marvell 88E3015 Manual page 66

Integrated 10/100 fast ethernet transceiver
Table of Contents

Advertisement

88E3015/88E3018
Integrated 10/100 Fast Ethernet Transceiver
Table 37:
Link Partner Ability Register (Base Page)
Register 5
B i ts
F i el d
15
LPNxt Page
14
LPAck
13
LPRemote
Fault
12:5
LPTechAble
4:0
LPSelector
Doc. No. MV-S103657-00, Rev. D
Page 66
M o d e
H W
S W
R s t
R s t
RO
0x0
0x0
RO
0x0
0x0
RO
0x0
0x0
RO
0x00
0x00
RO
0x00
0x00
Document Classification: Proprietary Information
D e s c r i p t io n
Next Page Mode
Base page will be overwritten if next page is received
and if Reg8NxtPg (16.12) is disabled.
When Reg8NxtPg (16.12) is enabled, then next page is
stored in the Link Partner Next Page register, and the
Link Partner Ability Register holds the base page.
Received Code Word Bit 15
0 = Link partner not capable of next page
1 = Link partner capable of next page
Acknowledge
Received Code Word Bit 14
0 = Link partner did not receive code word
1 = Link partner received link code word
Remote Fault
Received Code Word Bit 13
0 = Link partner has not detected remote fault
1 = Link partner detected remote fault
Technology Ability Field
Received Code Word Bit 12:5
Selector Field
Received Code Word Bit 4:0