8.4.2

Aligning with adjustable height frame

1.
2.
8.5

Make the electrical connection

Do this procedure if the appliance has a convection ventilator and/or an Opti-Air system.
1.
2.
3.
8.6

Connect the flue gas pipe

The appliance can be connected to steel pipes, double-walled insulated stainless steel
flues and flexible stainless steel flues with an outside diameter of 180 mm.
Preliminary requirements
If the appliance is installed on an unlined, masonry flue with a large diameter, use an
insulated flue lining system .
Procedure
1.
2.
3.
4.
Cuatro-7 75-60
If applicable, disconnect the 2 height
frames and connect these again on
the required height on the appliance.
Use a 10 mm socket spanner for the
4 screws. Make sure to attach each
height frame with all 4 screws.
Adjust the 4 adjustable feet with a 13
mm fork spanner until the appliance
is level. Use a spirit level.
Caution:
Use wall sockets with an earth connection.
The sockets must be accessible at all times.
Connect the 18V adapter of the Opti-Air system with the wall socket.
Connect the 230 VAC cable of the ventilator speed controller with the wall socket
Make sure that the electrical cables do not touch the appliance, due to the high
temperatures of the appliance.
Caution:
During operation of the appliance the outer side of the flue system
becomes hot. Refer to the installation instructions of the flue system for
safe installation. Follow these instructions with regard to safe distances to
combustible material.
Connect the flue to the flue gas connection on the appliance. If necessary use a steel
flue adaptor.
If a flexible stainless steel flue is used, secure the flue connection with 2 clamps.
If the flue is connected to an existing (masonry) chimney, make sure that the gap
between the flue and the existing chimney is sealed, with ceramic wool or any other
applicable component (ask your flue system supplier for advice)
Make sure that all mechanical connections of the flue system are correctly used.
Installation in a new fireplace