Clearances
5
Clearances
5.1
Insulating material requirements
•
Use insulating plates with a maximum thermal conductivity of 0.10 W/m.K or a thermal
resistance of minimum 10 K.m/W. The table hereunder shows some examples of
suitable insulating plate materials.
Examples of suitable plate material
Promat Promatect L insulating board
Skamol Skamotec 225
Skamol Super-Isol
•
Only use white unbound ceramic insulation wool. Do not use glass wool or rock wool,
these materials can cause a bad smell, unwanted smoke and is not applicable for high
temperatures.
Insulation wool property
Temperature resistance
Density
5.2
Clearances to flammable or load-bearing walls
Put a non-flammable insulation plate between the appliance and the rear wall and side
wall according the figure hereunder.
Obey the requirements as mentioned in the table hereunder.
20
Warning:
•
Obey the instructions in this section. Failure to follow these instruction can
create a fire hazard.
•
Do not put the appliance directly against a flammable or non-flammable
wall.
Caution: Make sure there is a 3 mm clearance between the appliance and
the surrounding construction, to allow for expansion of the appliance during
use.
Thermal conductivity
0.083 W/m.K
0.06 W/m.K
0.08 W/m.K
Requirement
> 700 °C
3
> 80 kg/m
Cuatro-7 75-60