Installation requirements

6.1
Requirements on the installation of the appliance in an
existing fireplace
This section refers to the installation of the appliance in an existing open (masonry)
fireplace.
Make sure that the location agrees with the safety requirements. Refer to section
Make sure the opening in the fireplace is large enough for a gap of 1 - 3 cm between
the appliance and the inner fireplace walls .
Make sure the floor can support the weight of the appliance. Refer to section
weight of the appliance.
Make sure that the floor temperatures in front of the appliance cannot be higher than
85 °C, during use of the appliance. Refer to section 5.7.
The non-combustible floor in front of the appliance must have a width that extends at
least 150 mm from each side of the appliance and a minimum depth in front of the
appliance according the requirements in section 5.7.
Make sure the room where the appliance is installed is properly ventilated.
Make sure that combustion air can flow into the appliance without obstruction.
If applicable, install a valve in the external combustion air pipe.
6.2
Requirements on the installation of the appliance in a new
fireplace
Make sure the floor is made of concrete or a solid pedestal of nonflammable material.
Make sure that the floor temperatures under and in front of the appliance are
maximum 85 °C, during use of the appliance. Refer to section
Make sure that the location agrees with the safety requirements. Refer to section 4.1.
Do not install the appliance against a combustible rear wall or combustible side wall.
Make sure to obey the clearances as listed in section 5.
Make sure the floor can support the weight of the appliance. Refer to section
weight of the appliance.
Make sure the room where the appliance is installed is properly ventilated.
Make sure that combustion air can flow into the appliance without obstruction.
If applicable, install a valve in the external combustion air pipe.
If the appliance is equipped with the optional convection ventilator, the combustion air
must be supplied from outside through a flexible aluminum pipe to the appliance.
Make sure there is an earthed wall socket for the power supply of the convection
ventilator and an earthed wall socket with for the power supply of the Opti-Air system.
These sockets must be accessible at all times.
Make sure the distance between the convection air outlet openings and the ceiling
above is at least 50 cm.
Make sure the distance between the convection air outlet openings and a neighboring
wall is at least 20 cm.
Cuatro-7 75-60
Installation requirements
4.1
11
for the
5.3
and section5.7.
11
for the
27