6
Installation requirements
6.1
Requirements on the installation of the appliance in an
existing fireplace
This section refers to the installation of the appliance in an existing open (masonry)
fireplace.
•
Make sure that the location agrees with the safety requirements. Refer to section
•
Make sure the opening in the fireplace is large enough for a gap of 1 - 3 cm between
the appliance and the inner fireplace walls .
•
Make sure the floor can support the weight of the appliance. Refer to section
weight of the appliance.
•
Make sure that the floor temperatures in front of the appliance cannot be higher than
85 °C, during use of the appliance. Refer to section 5.7.
•
The non-combustible floor in front of the appliance must have a width that extends at
least 150 mm from each side of the appliance and a minimum depth in front of the
appliance according the requirements in section 5.7.
•
Make sure the room where the appliance is installed is properly ventilated.
•
Make sure that combustion air can flow into the appliance without obstruction.
•
If applicable, install a valve in the external combustion air pipe.
6.2
Requirements on the installation of the appliance in a new
fireplace
•
Make sure the floor is made of concrete or a solid pedestal of nonflammable material.
•
Make sure that the floor temperatures under and in front of the appliance are
maximum 85 °C, during use of the appliance. Refer to section
•
Make sure that the location agrees with the safety requirements. Refer to section 4.1.
•
Do not install the appliance against a combustible rear wall or combustible side wall.
•
Make sure to obey the clearances as listed in section 5.
•
Make sure the floor can support the weight of the appliance. Refer to section
weight of the appliance.
•
Make sure the room where the appliance is installed is properly ventilated.
•
Make sure that combustion air can flow into the appliance without obstruction.
•
If applicable, install a valve in the external combustion air pipe.
•
If the appliance is equipped with the optional convection ventilator, the combustion air
must be supplied from outside through a flexible aluminum pipe to the appliance.
•
Make sure there is an earthed wall socket for the power supply of the convection
ventilator and an earthed wall socket with for the power supply of the Opti-Air system.
These sockets must be accessible at all times.
•
Make sure the distance between the convection air outlet openings and the ceiling
above is at least 50 cm.
•
Make sure the distance between the convection air outlet openings and a neighboring
wall is at least 20 cm.
Cuatro-7 75-60
Installation requirements
4.1
11
for the
5.3
and section5.7.
11
for the
27