Advertisement

DIRECTIONS FOR USE
200 L / 200 R / 300
NAME
Unilux-3 200 L
Unilux-3 200 R
Unilux-3 300
EN -13229
UNILUX-3
INSTALLATION INSTRUCTIONS
OUTPUT
8.0 kW
8.0 kW
8.0 kW
DESCRIPTION
Fireplace insert
Fireplace insert
Fireplace insert

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UNILUX-3300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for barbas UNILUX-3300

  • Page 1 DIRECTIONS FOR USE INSTALLATION INSTRUCTIONS UNILUX-3 200 L / 200 R / 300 NAME OUTPUT DESCRIPTION Unilux-3 200 L 8.0 kW Fireplace insert Unilux-3 200 R 8.0 kW Fireplace insert Unilux-3 300 8.0 kW Fireplace insert EN -13229...
  • Page 3: Unilux-3 200 L / 200 R

    UNILUX-3 200 L / 200 R / 300 UNILUX-3 200 R...
  • Page 4 UNILUX-3 200 L / 200 R / 300...
  • Page 5: Table Of Contents

    UNILUX-3 200 L / 200 R / 300 TABLE OF CONTENTS Page 1. Introduction 1.1 Preface................1.2 Safety................2. Location.................. 3. Installation instructions............4. Operation of the fi replace insert..........5. Stoking up for the fi rst time............. 6. Use 6.1 Ventilation...............
  • Page 6 UNILUX-3 200 L / 200 R / 300...
  • Page 7: Introduction

    1.1. PREFACE We would like to congratulate you on your purchase of this modern BARBAS fi replace insert. This quality product will give you years of heating pleasure as you enjoy the play of the fl ames and the cosy glow of the fi re.
  • Page 8 UNILUX-3 200 L / 200 R / 300 • Do not use your stove as a barbecue. This can cause (fl ammable) fat deposits to be left in the chimney and hastens the chimney becoming clogged. Prevent your chimney being soiled from above (birds’ nests etc.) by fi...
  • Page 9: Location

    UNILUX-3 200 L / 200 R / 300 LOCATION 2.1. INCLUDED Documentation Warranty Manual Attributes Glove (Heat resistant up to max. 95°C) Operating hook / Poker N.B. If any part is missing, please contact your dealer. 2.2. PREPARATION FOR POSITIONING Check all functions of the fi...
  • Page 10 UNILUX-3 200 L / 200 R / 300 Handle ± 50° forwards: The door releases from its lock and be opened forwards.
  • Page 11 UNILUX-3 200 L / 200 R / 300 • Check the operation of the slider for controlling the combustion air. • Check whether the ashtray is completely empty.
  • Page 12 UNILUX-3 200 L / 200 R / 300 • Report any defects immediately to your dealer. • Remove enclosed documents and components from the fi re. Have the suitability of the area in which the fi re is to be fi tted (and the chimney) approved by a specialist.
  • Page 13: Installation Instructions

    UNILUX-3 200 L / 200 R / 300 INSTALLATION INSTRUCTIONS 3.1. FITTING THE FIREPLACE When fi tting one of these fi replace inserts local and/or national regulations relating to fi re safety must be followed. In case of doubt, consult the fi re safety department of the local fi...
  • Page 14 UNILUX-3 200 L / 200 R / 300 3.3. FITTING A fi replace insert can be fi tted in the newly-built or existing chimney breast of an open fi re. When fi tting, both fi re safety and operational safety must be safeguarded.
  • Page 15 UNILUX-3 200 L / 200 R / 300 3.3.1. Aeration / ventilation A fi replace insert generates : - heating air - combustion air Heating air (convection air) is devoted to the convection of heat from the appliance to the room. No other provisions are necessary. The source of heat is in the room and stays there.
  • Page 16 UNILUX-3 200 L / 200 R / 300 3.3.2. Fitting in an existing chimney breast • Remove the existing fi re basket or stoking stones and remove the shut-off fl ap. The chimney must be intact and must not be damaged during fi tting. The chimney breast opening must be big enough for a gap of 1 - 3 cm to be left all round the appliance.
  • Page 17 UNILUX-3 200 L / 200 R / 300 Adjusting the built-in height of the appliance with the four adjustible legs 3.3.3. Fitting in a newly-built chimney breast • Clad the appliance on the top, sides and rear up to the front edge with an approx.
  • Page 18 UNILUX-3 200 L / 200 R / 300 Inlet opening (appliance) combustion air and “cold” convection air Outlet opening (appliance) “warm” convection air Inlet opening (grate) (chimney breast) “cold” ventilation air Outlet opening (grate) (chimney breast) “warm” ventilation air Figure 1: Use of ventilation of the fi replace Unilux-3 200 L / 200 R / 300 •...
  • Page 19 UNILUX-3 200 L / 200 R / 300 Available BARBAS grids (option) for ventilating the fi replace: COLOUR DIMENSION (cm) CLEAR OPENING (cm White 13.5 x 13.5 (incl. fi tting) White 27.0 x 13.5 (incl. fi tting) Perma Air (white) 43.0 x 22.0...
  • Page 20 UNILUX-3 200 L / 200 R / 300 • Disassembling the smoke outlet top-connection. • Pull the stovepipe or the stainless steel (fl exible) pipe downwards through the appliance and secure it to the smoke outlet connection. Stainless steel fl exible...
  • Page 21 UNILUX-3 200 L / 200 R / 300 Fix with hose clamp (Minimum 2 pieces per connection.) Stovepipe of steel • Push the smoke outlet connection back upwards and secure it in place. • Replace the brake plate and the complete interior.
  • Page 22: Operation Of The Fi Replace Insert

    UNILUX-3 200 L / 200 R / 300 OPERATION OF THE FIREPLACE INSERT Figure 2: Operation Unilux-3 200 L / 200 R / 300 Handle Ceramic heat-proof glass, front Smoke outlet (can be dismounted) Convection air escape opening (permanent) Internal panels (vermiculite plate) / Inner lining Ceramic heat-proof glass, side Grate Ashtray...
  • Page 23: Stoking Up For The Fi Rst Time

    UNILUX-3 200 L / 200 R / 300 STOKING UP FOR THE FIRST TIME If you have had your chimney breast modifi ed or newly built, fi rst allow your home to dry properly. Walls which have not been allowed to dry properly are a magnet for dust such as any smoke particles created when stoking up the fi...
  • Page 24: Use

    UNILUX-3 200 L / 200 R / 300 6.1. VENTILATION Air is a vital component of the combustion process. Ensure that there is a suffi cient supply of fresh air. For each kilo of wood that you put on the fi re (door closed), 10 - 15 m of extra air is needed.
  • Page 25 UNILUX-3 200 L / 200 R / 300 Control range of primary air supply (by grate) Control range of secondary and tertiary air supply Combustion air supply slider Centre position We recommend that you maintain a substantial layer of ash (2 - 3 cm). This not only forms a protective layer for the base of the appliance but also signifi...
  • Page 26: Heating Economically

    UNILUX-3 200 L / 200 R / 300 Ventilation When using the fi re, ensure a good supply of fresh air. After all, the combustion air is taken from the room where the fi re is located. Turn on the fl ue gas fan if the fl...
  • Page 27: Cleaning The Window

    UNILUX-3 200 L / 200 R / 300 6.5. CLEANING THE WINDOW After several burning hours, a light deposit may form on the inner side of the window. Once the fi re has cooled down, this deposit can be removed using glass cleaner or ceramic hob cleaner.
  • Page 28: General Hints

    UNILUX-3 200 L / 200 R / 300 GENERAL HINTS 7.1. TIPS • Burn dry wood only. Damp wood not only burns poorly, it causes more pollution in the appliance (window), the chimney, your room (when opening the door of the appliance, for instance) and the environment. Wood can only be classifi...
  • Page 29: Output

    UNILUX-3 200 L / 200 R / 300 • Chimney fi re. If, despite all the precautions, a fi re should occur in the chimney (you generally notice that because of a roaring sound in the chimney), do the following: •...
  • Page 30 UNILUX-3 200 L / 200 R / 300 • Excessive chimney draught. The combustion air does not reach the fuel, but leaves the appliance via the chimney. The fi re cools and the combustion quality decreases. • Using too much wood. This is a problem if your fi...
  • Page 31: Fuel

    UNILUX-3 200 L / 200 R / 300 FUELS 8.1. WOOD Suitable fuels are: • All sorts of clean wood (forested). The wood must have been dried for at least two years. Well-dried wood has a humidity percentage between 10 and 20%.
  • Page 32: Amount Of Fuel

    fi re, the hotter it will become and overheating may even occur. If this happens, there is a risk of fi re. It may also damage your appliance and chimney. BARBAS will not assume liability for damage caused by overheating.
  • Page 33 UNILUX-3 200 L / 200 R / 300 9.2. HEAT RADIATION The table below shows the temperatures which can theoretically be achieved by burning wood. Heat radiation Sort of fuel kWh/kg Dry wood (average) The heating value of wood (18.7 MJ/kg at 0% humidity) is not affected by the sort of wood.
  • Page 34: Regular Maintenance

    Check function annually • Convection channels Clean annually • Paint Annually, if necessary touch up with BARBAS heat-resistant paint (do not use with open fi res !) • Parts Individual parts for replacement/ accessories are available from your BARBAS dealer Use only original parts •...
  • Page 35: Replacement Parts

    UNILUX-3 200 L / 200 R / 300 REPLACEMENT PARTS 11.1 UNILUX-3 200 L Item no Description Number body smoke connection brake plate (vermiculite plate) internal panel rear, L/R (vermiculite plate) internal panel rear, middle (vermiculite plate) internal panel side, R (vermiculite plate) bottom plate, R (vermiculite plate) grate bottom plate, front (vermiculite plate)
  • Page 36 UNILUX-3 200 L / 200 R / 300 11.2 UNILUX-3 200 R Item no Description Number body smoke connection glass, side R side panel, R wood rack, side bottom plate, R (vermiculite plate) grate wood rack, front ashtray bottom plate, front (vermiculite plate) glass, front door bottom plate, L (vermiculite plate)
  • Page 37 UNILUX-3 200 L / 200 R / 300 11.3 UNILUX-3 300 Item no Description Number body smoke connection glass, side R side panel, R wood rack, side bottom plate, L/R (vermiculite plate) ashtray grate bottom plate, front (vermiculite plate) wood rack, front glass, front door glass, side L...
  • Page 38 UNILUX-3 200 L / 200 R / 300 Sequence for replacing the interior of the appliance: Remove the grate. Remove the ashtray. Remove the wood rack in the front. - Remove the bottom plate in the front. Remove the bottom plate, L and R.
  • Page 39 UNILUX-3 200 L / 200 R / 300 Lift the brake plate and turn the brake plate bracket to the back. Remove the brake plate. Disassemble the air guidance strip.
  • Page 40 UNILUX-3 200 L / 200 R / 300 Remove the side internal panel. Remove the rear internal panel.
  • Page 41 UNILUX-3 200 L / 200 R / 300 The entire interior is now disassembled. The interior is reassembled in the reverse order.
  • Page 42: Dimensions

    UNILUX-3 200 L / 200 R / 300 DIMENSIONS 12.1 UNILUX-3 200 L...
  • Page 43 UNILUX-3 200 L / 200 R / 300 12.2 UNILUX-3 200 R...
  • Page 44 UNILUX-3 200 L / 200 R / 300 12.3 UNILUX-3 300...
  • Page 45: Technical Data

    UNILUX-3 200 L / 200 R / 300 TECHNICAL DATA UNILUX-3 200 L / 200 R / 300 Combustion: Measured in compliance with EN 13229 : 2001 and EN 13229 - A2 : 2004 Fuel Wood Output; min. - max. 5 - 11 kW Nominal output 8 kW...
  • Page 46: Frequently Asked Questions

    Can a wood-burning stove/fi replace insert be connected to a central heating installation? The Barbas range does not have any stoves/fi res that can be connected to central heating installations. We do not advise attempting it!! How do I know if I’m heating correctly? Follow the instructions in this manual.
  • Page 47 UNILUX-3 200 L / 200 R / 300 What is wrong with a smoking chimney? A seriously smoking chimney means that combustion is less than optimum. There may be a number of reasons for this. If the fi re has only just caught on, or has recently been topped up, some smoke is normal.
  • Page 48 UNILUX-3 200 L / 200 R / 300 Do I have to take any extra measures if the room I am heating has an extractor fan (mechanical ventilation)? A fl ue gas fan is required for permanent extraction of the area in which the fi...
  • Page 49 UNILUX-3 200 L / 200 R / 300...
  • Page 50 UNILUX-3 200 L / 200 R / 300...
  • Page 52 INTERFOCOS B.V. HALLENSTRAAT 17 5531 AB BLADEL NEDERLAND E-mail: info@barbas.nl Internet: www.barbas.com 01 - 010710 - 328164...

This manual is also suitable for:

Unilux-3200 lUnilux-3200 r

Table of Contents