Clearance To Flammable Floor (Under The Appliance); Clearances To Flammable Ceiling - barbas Cuatro-7 75-60 Installation And Maintenance Manual

Hide thumbs Also See for Cuatro-7 75-60:
Table of Contents

Advertisement

1
2
Item
A
B
C
D
E
F
5.3

Clearance to flammable floor (under the appliance)

Put a non-flammable insulation plate with a minimum thickness of 3 cm under the
appliance. To avoid damage to this non-flammable plate, put ceramic or steel tiles
(approx. 10 x 10 cm) under the feet of the appliance.
5.4

Clearances to flammable ceiling

Cuatro-7 75-60
E
F
Non-flammable spacer
Non-flammable insulation plate
Air gap
Thickness plate
Air gap / Spacer
A+B+C
B+C
Minimum 3 mm clearance between appliance and surrounding construction
Note:
If a wooden beam is present above the appliance, make sure to protect it
against direct heat radiation. Make sure to put a non-flammable insulation
plate with a thickness of minimum 3 cm between the wooden beam and the
appliance. with an air gap of minimum 1 cm between the insulation plate and
the wooden beam.
1
2
3
A
B
C
D
3
Flammable or load-bearing wall
Dimension
2.5 cm
10 cm
2.5 cm
15 cm
12.5 cm
Clearances
1
A
F
E
B C
B
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cuatro-7 75-60 opti-air

Table of Contents