Clearances
5.6

Clearances to a non-flammable ceiling

Put a non-flammable insulation plate (false ceiling) of minimum 5 cm thickness at a height
of minimum 50 cm above the appliance.
Obey the dimensions mentioned in the tabel hereunder.
1
2
3
h
H
A
24
B
H
Chimney enclosure
Convection air outlet opening
Non-Flammable ceiling
Area of the convection air outlet opening
Height of the false ceiling
Distance between convection air outlet
opening and ceiling
3
4
h
4
Insulation plate (false ceiling)
5
Insulation plates
Dimensions
Minimum 300 cm
Minimum 5 cm (= thickness false ceiling)
Minimum 50 cm