Simrad CP60 Installation Manual
Making sure that all CP60 system cables are properly
connected
The CP60 system relies on communication between each unit, and between the CP60
system and external devices. It is very important that all cables are correctly installed,
that the proper cable types have been used, and that all cables are connected correctly.
Prerequisites
The CP60 system hardware units are installed as specified in this manual.
• The CP60 system is turned off.
• All system cables are installed.
• All cable connections are made.
You need the following equipment:
• Cable tester
• Multimeter
Context
All cabling is described in the Cable layout and interconnections chapter. Refer to the
cable plan, the cable list and the basic cable requirements.
Procedure
1
For each cable in use on the CP60 system:
a
Make sure that the cable is installed as specified in the Cable layout and
interconnections chapter.
Pay special attention to signal cables. These must not be installed too close
to power cables.
b
Make sure that the terminations at each end of the cable are correct.
c
Make sure that the cable is properly identified.
2
If possible, use a multimeter or a dedicated cable tester to check the continuity
in each cable.
3
Use a qualification tester to make sure that each Ethernet cable is correctly wired,
and meets the specifications related to quality and bandwidth.
4
If irregularities are found, write these down in the in the Installation remarks table.
Result
Requirements
All cables are properly connected.
All cables are properly identified with labels or other types of markings.
Each Ethernet cable in use is correctly wired.