Simrad CP60 Installation Manual
All measurements must be made after the installation of the transducer and the
navigation sensors
Procedure
1
Define the vessel coordinate system.
2
Define the location of the origin in the coordinate system. If required, identify
the location with a physical marking.
3
Set out the required coordinate reference points throughout the vessel.
4
Define the vessel's centre line. If required, identify the line with physical markings.
5
Measure the physical location of each transducer.
6
Measure the physical location of the motion reference unit (MRU).
7
Measure the physical location of the global positioning system (GPS) antenna.
Result
The information provided by the dimensional survey is entered into the CP60 software as
installation parameters.
Related topics
Setting to work, page 108
Placing each sensor in the vessel coordinate system, page 138
Vessel coordinate system, page 143

Example procedure

It is not within the scope of this publication to provide detailed instructions for
dimensional surveying. However, an example procedure is provided to help you
understand how it is done.
Prerequisites
For accurate ship dimensions you need the detailed vessel drawings. You need a printed
version of each drawing. Each drawing must be to scale.