(8) Description of MENU 6 Functions

For operation details, refer to the ASP-80 manual.
MENU6 <SETUP> (ASP-80) 
1.ZERO CARIBRATION 
2.AWB(6500K)                
3.AWB(9300K)                
4.AWB(USER DATA)            
5.MEASUREMENT & MEMORY      
6.REAL TIME MEASUREMENT     
 
 
NEXT    →(MENU) 
SELECT→(ENT)      EXIT→(ESC)
① Zero calibration
Perform the calibration of Auto setup probe.
Connect ASP-80 to the monitor, and make sure to
perform this calibration before proceeding onwards.
The function is disabled unless Auto setup probe
is connected.
Be careful not to allow external light into the sen-
sor.
When the sensor is not receiving light to be mea-
sured, the message "ERROR 1 : TOO LIGHT"
appears.
② Auto white balance (6500K)
Setup at 6500K
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.
③ Auto white balance (9300K)
Setup at 9300K
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.
④ Auto white balance (User data)

(9) Description of MENU 7 Functions

* This menu is intended to control the embedded audio module DKM-5**AV/AVD and the embedded audio level
meter module DAM-504/508.
The setting in this menu does not function for a monitor without the above modules.
MENU7 <AUDIO> 
1.LINE  OUT CH 
CH1/2 
2.LED ENABLE 
CH1to8 
3.LED DIMMER 
HIGH 
 
 
NEXT    →(MENU) 
SELECT→(ENT)      EXIT→(ESC)
① Setting the analog audio output
Select the DKM-5**AV analog audio line output
(2ch) from the four pairs of enbedded audio chan-
nels CH1/2, CH3/4, CH5/6 and CH7/8.
This function is disabled for the embedded digital
audio output model (DKM-5**AVD).
② Setting the channel of level meter
Select the display channel of DAM-504/508 from 8-
channel (CH1 TO 8), 6-channel (CH1 TO 6), 4-chan-
nel (CH1 TO 4) and 2-channel (CH1 TO 2) as nec-
essary.
① Zero calibration 
② Auto white balance (6500K) 
③ Auto white balance (9300K)             
④ Auto white balance (User data) 
⑤ Color temperature/luminance measurement and memory 
⑥ Real-time color temperature/luminance measurement
① Setting the analog audio output 
② Setting the channel of level meter 
③ Setting the brightness of level meter
38
Setup at user color temperature.
To execute this setup, an input of 100% window
signal or the window pattern internal test signal
is needed.
⑤ Color temperature and luminance measure-
ment and memory
Measure the color temperature, luminance and ras-
ter luminance of the user setting.
The results can be stored as USER DATA if neces-
sary.
Measurable ranges are as follows.
Luminance:
Raster luminance:
Color temperature (x, y coordinates):
⑥ Real-time color temperature and luminance
measurement
Color temperature and luminance are measured
for real-time display of the readings.
The function can also be applied to the measure-
ment of other devices.
For DAM-504 (4-channel model), the selections of
8-channel and 6-channel are disabled.
③ Setting the bightness of level meter
Select the brightness of DAM-504/508 level meter
LED from HIGH, MID, LOW and OFF.
The setting is not applied to the tally (red and
green).
10~190cd/ ㎡
0.01~0.99cd/ ㎡
0.250~0.380