Ikegami HTM-1517R Operation Manual

Multi format color monitor
Hide thumbs Also See for HTM-1517R:
Table of Contents

Advertisement

Quick Links

MODEL
HTM-1517R
HTM-1917R
MULTI FORMAT
COLOR MONITOR
OPERATION MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Ikegami HTM-1517R

  • Page 1 MODEL HTM-1517R HTM-1917R MULTI FORMAT COLOR MONITOR OPERATION MANUAL...
  • Page 3 The “CE” mark means the products as mentioned below will meet the intent of the following Directives and Standards. Inrush current according to EN55103-1 Annex B is as 43.8A (HTM-1517R) Directives : 93/68/EEC, 89/336/EEC, 92/31/EEC for EMC (electromagnetic compatibility) 73/23/EEC for Low voltage (Safety)
  • Page 4 IMPORTANT SAFETY INSTRUCTION 3) When connecting and disconnecting the 1. General power cable, be sure to hold the plug. 1) Read all instructions provided. 4) Do not allow anything to rest on the power 2) Save these instructions for future use. cord.
  • Page 5 3) Upon completion of any service or repairs to paint may peel away. this monitor, ask the service technician to perform routine safety checks to determine that the television is in safe operating condition. 4) For repair service, contact Ikegami’s authorized sales representative or Ikegami service desk directly.
  • Page 6 In such cases, contact the Ikegami 4) If cabinet or screen is dirty, wipe with soft service desk.
  • Page 7: Precautions Upon Use

    Malfunctions occurring in normal use within one year from the date of purchase will be repaired free of charge. This does not apply to the fuses. If no image is displayed after user adjustment or if malfunction is suspected, contact your nearest Ikegami dealer. Accessories This monitor is provided with the following accessories.
  • Page 8: Table Of Contents

    (5) Description of MENU 3 Functions ..36 2-4 External View ........(6) Description of MENU 4 Functions ..37 (1) HTM-1517R ..........(7) Description of MENU 5 Functions ..37 (2) HTM-1917R ..........(8) Description of MENU 6 Functions ..38 (3) HTM-1917R (9) Description of MENU 7 Functions ..
  • Page 9: Outline

    Easily visible LED meter installed in the escutch- video and audio monitoring with a single unit. eon will not obstruct video monitoring. Integrated The basic performance of the HTM-1517R remains with the monitor, the meter requires no extra space. the same. Compared with rack-mounted type, the...
  • Page 10 BFS (Beam feedback system) Use of high performance in-line gun CRT By adopting a BFS circuit for detecting CRT cath- A high performance in-line gun CRT of 0.25mm dot ode current, stable black balance can be obtained mask pitch is adopted to produce fine images with re- for a long period of time even when the CRT emis- duced reflection of external light.
  • Page 11: General Specifications

    External sync: External sync input level 0.3 to 6Vp-p 60Hz~5.75MHz: ±1dB 5) High voltage More than 5.75MHz:Descending response Generated voltage: HTM-1517R : 25kV ± 1kV 2) Sag: Within 5% HTM-1917R : 26kV ± 1kV 3) Black level stability: High voltage fluctuation: For 10% to 90% APL changes: Within 1% Within ±0.5% (150µ...
  • Page 12: Functions

    (5) Functions 7) Menu assist • Input signal format setting 1) Marker function • YPbPr/RGB switching setting a) Center marker: Set to ON/OFF using MENU settings • Test signal format setting b) Safe title: • Marker center cross display ON/OFF setting The following markers are displayed according to •...
  • Page 13: Multi-Format Sdi Input Module

    3) Input level b) SD-SDI(4:2:2) a) HDTV (BTA S-001B) • 480i/59.94 •Y, G, B, R input V: 700mVp-p Positive polarity • 575i/50 S: ±300mVp-p 3) Input level rating: 800mVp-p±10% •Pb, Pr input V: ±350mVp-p Positive polarity 4) Transmission speed •Sync input: ±300mVp-p a) HD-SDI: 1.485Gb/s...
  • Page 14: Sd-Sdi Input Module

    AES/EBU output (AVD type) DAM-508 : 8 channels * Digital audio level 0dBFS, full bit in full scale 5) Display segment: 13 segments 6) Display device: -∞~-25dB : Green LED 1) Output connector: -20~0dB : Amber LED BNC (Paired channel) 4 lines 2) Output standards: 2-3.
  • Page 15 Table 2-3. All combinations of optional slots Module DKM-511 DKM-511 DKM-511 AVD DK-801A DE-801 DE-811 Note1 Note1 Note1 Slot width No. of inputs MultiI-SDI x 2 Multi-SDI x 2 Multi-SDI x 2 4:2:2 x 2 NTSC x 3 NTSC/PAL-B x 3 No.
  • Page 16: External View

    2-4. External View (1) HTM-1517R...
  • Page 17: Htm-1917R

    (2) HTM-1917R...
  • Page 18: Htm-1917R (With Dam-504/508, Mk-1905)

    (3) HTM-1917R (with DAM-504/508, MK-1905)
  • Page 19: Installation

    3. Installation Caution: For your safety, turn off the power of each equipment before connection. 3-1. External connection (1) Standard module (MPU, VIDEO PROCESS) MPU module Option module *Refer to the pages that follow. VIDEO PROCESS module YPbPr/RGB A channel input REMOTE YPbPr/RGB •...
  • Page 20: Multi-Format Sdi Input Module

    (2) Multi-format SDI input module DKM-511* SDI A/B signal input  • Input the HDTV or SDTV (4:2:2) signal here.  HD / 4:2:2 • Input signal format is automatically identified to control the monitor.  CH A   CH B SDI signal output • Output the same selected channel signal from the A/B channel as channel select is made for     monitoring. MONITOR DKM-511*AV (compatible with 2 embedded analog audio outputs) AUDIO LINE OUT AUDIO LINE OUT •...
  • Page 21: Sd-Sdi Input Module

    (3) SD-SDI input module DK-801A 4:2:2 SD-SDI A/B input • Input the 4:2:2 SD-SDI signal here according to the following module.  CH A • When this module and multi SDI module are mounted together, this module will be assigned to the     2nd slot.  To select the 2nd slot, press the 2nd slot switch.    SD-SDI A output • The SD-SDI signal input to the A channel output here. CH B SD-SDI B output <Setting Method> • The SD-SDI signal input to the B channel is   MONITOR NORMAL(Default) MONITOR OUT   output from here.  • The signal selected at the monitor can also be    ...
  • Page 22: Parallel Remote Connection

    3-2. Parallel Remote Connection (1) Pin function CH-B ON CH-C ON Green TALLY ON YPbPr/RGB ON SD-SDI ON MONO ON RGB ON EXT-SYNC ON 16 : 9 ON MARKER ON <Connector Face View on Rear Panel> SHADOW ON Red TALLY ON HD-SDI/MULTI-SDI ON <Wiring of Remote Connector> Pin No. Function External Assignment for Function GND ON...
  • Page 23: User Adjustment

    ② AC power input   Insert the provided AC cable here to supply AC power.  AC IN   ③ Lock   After inserting the AC plug, lock the AC plug with this lock to prevent it from disconnecting.    AC100-120V   Fig. 4-1. POWER Section on Rear Panel (common for HTM-1517R and HTM-1917R) 4-2. Names and Functions of Front Left Panel Parts ①  ⑤  ④  ②  ③  ①  ② ...
  • Page 24: Names And Functions Of Front Controller Parts

    COMB ⑮ HUE manual switch and control ⑫ COMB switch PRESET CHROMA MARK ⑯ CHROMA manual switch and control ⑬ MARKER switch BRIGHT DELAY ⑰ BRIGHTNESS manual switch and control ⑭ DELAY switch FILE CONT ⑱ CONTRAST manual switch and control ⑲ FILE LED PUSH Fig. 4-3-1. HTM-1517R Front Panel ① INPUT SELECT switch ② DIGITAL switch ③ YPbPr/RGB switch ⑦ MONO(SPLIT) switch ⑧ APT switch ⑨ ASPECT switch ⑩ SCAN switch ⑭ DELAY switch ⑲ FILE LED INPUT SELECT MONO FUSE HTM-1917R DIGI YPbPr/RGB SPLIT ASPECT SCAN...
  • Page 25 Meaning of abbreviations in the following description b) For decoder module • SDTV: 480i, 575i The DE-811 is assigned to the 2nd SLOT. • HDTV: 1035i, 1080i, 480p, 720p ⑤ TEST switch • SD-SDI: SDTV(480i, 575i)SDI • HD-SDI: HDTV(1035i,1080i,720p)SDI Turn ON to switch to the internal TEST signal. The following standard TEST signal formats are pro- vided.
  • Page 26 ⑦ MONO (SPLIT) Switch ⑩ SCAN switch Set the MONO switch to ON when the color signal Use the SCAN switch to switch between normal is to be viewed in the black/white state. scan and under-scan. When the MONO switch is ON with the NTSC com- ⑪...
  • Page 27 ⑯ CHROMA manual switch and control This control serves as a MANUAL/PRESET data selection switch as well as a manual data variable control. The control pops out and is switched to the MANUAL state with each press (the LED lights). By rotating the control in this state, the manual data can be varied.
  • Page 28: Names And Functions Of Drawer Panel Controls

    G.BACKGROUND switch B.BACKGROUND switch FILE 1 switch G.GAIN switch HUE PRESET switch B.GAIN switch FILE 2 switch BRIGHTNESS PRESET switch CHROMA PRESET switch FILE 3 switch CONTRAST PRESET switch ESC switch MENU switch U.DISPLAY switch ENT switch Rotary Encoder ASP-80 connector Fig. 4-3-6. HTM-1517R Drawer Panel Controls MENU switch ENT switch ESC switch STORE PRESET switch U.DISPLAY switch CLEAR switch FILE 1 switch CHANGE PRESET switch FILE 2 switch FORCED COL/MONO switch FILE 3 switch MATRIX IN switch DISPLAY SELECT STORE CHANGE FORCED...
  • Page 29 ① MATRIX IN switch ④ EXT SYNC switch This switch is used to change the matrix ratio Set this switch to EXT when externally synchro- between luminance and color-difference signals. nizing the analog input signal. The switch does At the ON (LED on) position, the matrix level is not function when digital signals are input.
  • Page 30 a) APT PRESET switch ⑪ WIDTH  switch Set the APT switch on the front panel to ON. Switch for adjusting the width of the active screen b) HUE PRESET switch by scan size and aspect. When the HUE MANUAL switch on the front panel is ON, set it to PRESET.
  • Page 31 ⑱ R. BACKGROUND  switch Switch for adjusting the low light white balance FILE 2  switch 2 7  (blue component). Set this switch to ON to output or store data in For details of the adjustment, refer to 4-6 (3). FILE 2. ⑲...
  • Page 32: Storing And Changing Data In The Memory

    4-4. Storing and Changing Data in the Memory (1) Storing and changing the PRESET data <Example 1> Changing the MK.PHASE, H.CENT, V.CENT, WIDTH, HEIGHT, TRAPEZOID and SIDE PIN. Set  the  SCAN  size  to  the  UNDER  SCAN  mode  using  the  SCAN  switch, ...
  • Page 33: Changing And Storing The File Data

    <Example 2> Changing APT INPUT SELECT MONO FUSE DIGI YPbPr/RGB HTM-1917R SPLIT ASPECT SCAN DELAY CHROMA BRIGHT CONT FILE COLOR MONITOR MANUAL Set the  APT  switch to ON. TEST COMB MARK SLOT STNC SCREENS PRESET D I S P L AY S E L E C T F I L E S TO R E CHANGE...
  • Page 34: Types Of Markers

    4-5. Types of Markers ① 80% MARKER ⑬ 14:9 MARKER      Active screen area  Active screen area    100% area marker  14:9 area      80% area marker   ② 88% MARKER ⑭ 14:9 MARKER + SHADOW     Active screen area  Active screen area    100% area marker  14:9 marker    88% area marker 14:9 shadow ③ 90% MARKER ⑮ 14:9 SHADOW         Active screen area    Active screen area      100% area marker   ...
  • Page 35: Adjustment Procedure

    4-6. Adjustment Procedure Adjustments (1) thru (4) can be made more precisely by getting the space around the monitor as dark as possible. (1)Adjusting the brightness REFERENCE : 6500K a) Brightness FILE 1 6500K Brightness adjustment is to set the appropriate FILE 2 9300K black level.
  • Page 36: Adjusting The Color Balance

    Set only the B.SCREEN switch to ON (blue screen Return the SET UP and SCREEN switches to only), adjust the B.BACKGROUND data so that their original settings (OFF), and do not move the blue line at Part B in the Fig. 4-6-2 illumi- R.BACKGROUND thereafter.
  • Page 37: Adjusting The Focus

    (4) Adjusting the color balance ② Starting a) Color balance Set the screen to blue only using the SCREEN For the component signal (YPbPr/RGB), adjust the switch. color balance using CHROMA only. If the decoder * As the luminance difference is hard to discern module DE-801 or DE-811 is mounted, input NTSC when the screen is bright, dim the surroundings composite signal, and adjust the color balance us-...
  • Page 38: Adjusting The Rotation

    (6) Adjusting the rotation c) Adjustment procedure a) Rotation Perform the following adjustment once for each sig- ROTATION is the control for correcting changes nal format. in the purity caused by geomagnetic effects on the ① Input signal CRT which occur when the monitor is rotated. Check the MENU 1 format is set properly to the Perform this adjustment every time the monitor is signal format to be changed.
  • Page 39: Adjusting The Screen Size

    UNDER SCAN size in Set the EXPAND switch to ON again. The SIDE the following table. PIN adjustment mode is entered. Correct the side <UNDER SCAN Sizes> pin distortion as shown in the figure below. HTM-1517R ASPECT FORMAT HEIGHT WIDTH 4 : 3...
  • Page 40: Adjusting The Moiré Effect

    For details of the format setting, refer to 4.7(3) in <HDTV4:3 SCAN Sizes> this manual. HTM-1517R Input a crosshatch signal or select the crosshatch ASPECT HEIGHT WIDTH internal TEST signal.
  • Page 41: Menu Functions

    4-7. MENU Functions (1) List of MENU All functions can be executed in the MENU screen. Table 4-1 List of MENU MENU  MENU1  ① MULTI SDI FM  Setting the format of SDI inputs    <FORMAT>     ② RGB/YPBPR FM  Setting the format of RGB/YPbPr inputs       ③ →1035I/1080I  Setting the format of RGB/YPbPr input line       ④ →YPBPR  Setting the format of RGB/YPbPr input signal       ⑤ TEST SIG. FM ...
  • Page 42: Flow Of Menu Operations

    (2) Flow of MENU Operations MENU can be switched as follows using the MENU switch. < Normal Screen >  MENU  switch ON MENU1 <FORMAT>→ 1080I/60     Set the format of each input signal. 1.MULTI SDI FM  AUTO     2.RGB/YPBPR FM   HDTV  3. →1035/1080I  1080I/60     4. →RGB/YPBPR   YPBPR       5.TEST SIG. FM   525I/60      ESC switch ON 6.INPUT DISP.  ON    NEXT    →(MENU)  SELECT→(ENT)       EXIT→(ESC)    MENU  switch ON MENU2 <MODE> ...
  • Page 43: Description Of Menu 1 Functions

    (3)Description of MENU 1 Functions Note the following description on the menu. The vertical deflection frequency /60 includes both 60 Hz and 59.94 Hz. The vertical deflection frequency /48 shows 24 sF (23.98 sF). 480i/59.94 and 575i/50 are displayed as 525I/60 and 625I/50, respectively. MENU1 <FORMAT>→ 1080I/60    ...
  • Page 44: Description Of Menu 3 Functions

    ⑤Setting the operation mode at aspect change ⑧ Setting the degauss ON timer Associate the change of aspect settings with the Set the operation start time of the degauss (de- switching of inputs. magnetization) function, which operates automati- AUTO: Display with the aspect ratio preset for cally when the power is turned on, using 0 ~ 9 each channel.
  • Page 45: Description Of Menu 4 Functions

    4-digit password here. released. If you forgot your password, contact the nearest ALL LOCK: Ikegami dealer. Change of all PRESET data and switching of FILE We will provide a password to exit the LOCK mode. are disabled.
  • Page 46: Description Of Menu 6 Functions

    (8) Description of MENU 6 Functions For operation details, refer to the ASP-80 manual. MENU6 <SETUP> (ASP-80)  1.ZERO CARIBRATION  ① Zero calibration  2.AWB(6500K)                 ② Auto white balance (6500K)  3.AWB(9300K)                 ③ Auto white balance (9300K)              4.AWB(USER DATA)             ④ Auto white balance (User data)  5.MEASUREMENT & MEMORY       ⑤ Color temperature/luminance measurement and memory  6.REAL TIME MEASUREMENT      ⑥ Real-time color temperature/luminance measurement     NEXT    →(MENU)  SELECT→(ENT)      EXIT→(ESC) ① Zero calibration Setup at user color temperature. Perform the calibration of Auto setup probe. To execute this setup, an input of 100% window Connect ASP-80 to the monitor, and make sure to signal or the window pattern internal test signal...
  • Page 47: Messages Displayed On The Screen

    4-8 Messages Displayed on the Screen Message Explanation Cause: This message is displayed during the LOCK mode (see 4.7(7)) or when FILE 1 , FILE 2 or FILE 3 switch is pressed. ALL LOCK Action: Release the LOCK mode (UNLOCK), and resume the operation. Cause: This message is displayed when CHANGE PRESET switch or STORE FILE switch is pressed during the PRESET FILE setting in the LOCK mode (see 4.7(7)).
  • Page 48: Installation Of Options

    5. Installation of Options 5-1 Option Module <Notes> • Modules should be inserted into the slots specified in the figure below. • Optional modules should be inserted into the slot Nos. 2-5. (The figure below is an example. These modules may not be installed in the product you purchased.) •...
  • Page 49: Rack Mount Adapter

    5-2 Rack Mount Adapter (1)RS-1550S Rack Mount Adapter for HTM-15**R *marks are attachments for the slide rail. ①  SLIDE RAIL (RACKSIDE) BRACKET *  * *  *  ②  MONITOR RACK METAL MCB4-12FZ N1H5FZ SLIDE RAIL  (MONITOR SIDE) MCB4-8FZ HOLE CAP RACK SCREWL WASHER ③ ...
  • Page 50 (2)RS-2020S Rack Mount Adapter for HTM-19**R/20**R ①  SLIDE RAIL (RACKSIDE) BRACKET *  * *  *  ②  MONITOR RACK METAL MCB4-12FZ N1H5FZ SLIDE RAIL  (MONITOR SIDE) MCB4-8FZ HOLE CAP RACK SCREWL WASHER ③ ...
  • Page 51: Remote Controller

    5-3 Remote Controller (1)RCT-30A Infrared Remote Controller MONITOR SELECT CALL MONO INPUT DELAY SCAN COMB SYNC DEGAUSS FILE MENU MARKER WHITE BALANCE CHANGE CLEAR PRESET REMOTE CONTROL RCT-30A...
  • Page 52: Src-301Z Serial Remote Controller

    (2)SRC-301Z Serial Remote Controller 45.2 1 110 1 37.2 1 POWER SRC-301Z SERIAL REMOTE CONTROLLER MENU CLEAR WHITE BALANCE PRESET STORE CALL COMPOSITE TYPbPr/RGB C(Y/C) TEST HD-SDI BLUE TRAP/ COMB/ D-PAL S-PAL COLOR MONO SCAN 4 : 3 16 : 9 UNDER S.
  • Page 53: Memo

    6. Memo Although various PRESET DATA has data of the following kinds, write down customized PRESET DATA for your memorandum. If you have modified the PRESET DATA unintentionally, you can restore the default setting by executing LOAD FACTORY in MENU 3-4. DATA REF.
  • Page 55 © May 2007 by Utsunomiya Factory of Ikegami Tsushinki Co., Ltd. ■ All right reserved. Reproduction or duplication, without permission of Ikegami Tsushinki Co., Ltd. of edition or contents in whole in part, any manner, is prohibited. ■ Specifications and design are subject to change without notice.
  • Page 56 Ikegami Tsushinki Co., Ltd. 5-6-16, Ikegami, Ohta-ku, Tokyo, Japan 146-8567 Phone:(03)5700-1111 Fax:(03)5700-1137 Ikegami Electronics (U.S.A.), Inc. 37 Brook Avenue, Maywood, New Jersey 07607 Phone:(201)368-9171, Fax:(201)569-1626 Ikegami Electronics (Europe) GmbH Ikegami Strasse 1, D-41460 Neuss, Germany Phone:(02131)123-0, Fax:(02131)102820 Property of PRINTED IN JAPAN...

This manual is also suitable for:

Htm-1917r

Table of Contents