Reference mark selector and limit magnet installation

IMPORTANT: Allow 24 hours after the scale application before fitting the magnets.
For accuracy and ease of positioning of the reference mark selector and limit magnets, the
applicator tool should be used. The magnet should be attached to the applicator tool as shown.
Limit magnets can be positioned at any user defined location along the scale, but the reference
mark selector magnet (T3010 readheads only) should be positioned adjacent to the selected
IN-TRAC reference mark as shown.
As the TONiC FS readhead passes the reference mark selector magnet or limit switch magnet,
a force of up to 0.2 N is generated between the magnet and the concentrators on the readhead.
The design of the bracket should be sufficiently stiff so that it is able to tolerate such force
without distorting.
Following the scale installation instructions will prevent this magnetic force from disturbing
the scale.
Limit trigger point
The limit output is nominally asserted when the readhead limit switch sensor passes the limit
magnet leading edge, but can trigger up to 3 mm before that edge (see
installation drawing'
on page 23).
NOTES:
The reference and limit magnets may creep when influenced by magnetic materials in close
proximity. In such cases, they should be held in place using an additional fillet of epoxy glue
or similar along the outer edge of the magnet assembly.
The reference mark selector and limit actuator locations are correct for the readhead
orientation shown.
The reference mark selector magnet is only required for RSLC20 scale with T3010
readheads.
External magnetic fields greater than 6 mT, in the vicinity of the readhead, may cause false
activation of the limit and reference sensors.
32
TONiC™ FS RELM20/ RSLM20 Functional Safety installation guide and safety manual
P limit magnet
'TONiC T3x1x readhead
Magnet applicator tool
Remove self-adhesive
backing paper
Selected IN-TRAC
reference mark
Reference mark
selector magnet
Q limit magnet