ADI Confidential
DC-TO-DC CONVERTER BLOCK SPECIFICATIONS
T
= 25°C, V
= V
= 3.6 V, V
J
VBATT
VDD
Table 2.
Parameter
CHANNEL 1 BOOST REGULATOR
Channel 1 Output Voltage (V
Adjustable Range, 3 Bits
Voltage Accuracy
Load Regulation
Line Regulation
Switching Node (SW1 Pins)
High-Side Power FET, R
DS(ON)
Low-Side Power FET, R
DS(ON)
Low-Side Switch Current Limit
Minimum Off Time
Soft Start Time
Power Save Mode (PSM)
Output Voltage on PSM
PSM SW1 Low-Side Power FET, R
PSM On Time
CHANNEL 2 BUCK-BOOST REGULATOR
Channel 2 Output Voltage (V
Adjustable Range, 3 Bits
Voltage Accuracy
Load Regulation
Line Regulation
Switching Node (SWA2 Pins)
High-Side Power FET, R
DS(ON)
Low-Side Power FET, R
DS(ON)
High-Side Switch Current Limit
Switching Node (SWB2 Pins)
High-Side Power FET, R
DS(ON)
Low-Side Power FET, R
DS(ON)
Minimum Off Time
Soft Start Time
C
Discharge Switch On Resistance
OUT
CHANNEL 3 BUCK REGULATOR
Channel 3 Output Voltage (FB3 Pin)
Adjustable Range, 4 Bits
Feedback Voltage Accuracy at Default VID Code
Load Regulation
Line Regulation
Switching Node (SW3 Pins)
High-Side Power FET, R
DS(ON)
Low-Side Power FET, R
DS(ON)
Switch Current Limit
Soft Start Time
C
Discharge Switch On Resistance
OUT
= 3.3 V, unless otherwise noted.
VDDIO
)
OUT1
DS(ON)
)
OUT2
Symbol
Min
Typ
V
3.8
OUT1
V
−1.5
OUT1(DEFAULT)
−2.5
∆V
/I
−0.2
OUT1
LOAD
∆V
/V
0.1
OUT1
VBATT
R
100
DS(ON)1H
R
115
DS(ON)1L
I
3
3.4
CL1
t
100
OFF1(MIN)
t
4
SS1
V
3.6
OUT1PSM
R
1
DS(ON)2L
t
450
ONPSM1
V
3.3
OUT2
V
−1.5
OUT2(DEFAULT)
−2.5
∆V
/I
−0.4
OUT2
LOAD
∆V
/V
0.1
OUT2
PVIN2
R
95
DS(ON)PRI2H
R
120
DS(ON)PRI2L
I
2
2.5
CL2
R
100
DS(ON)SEC2H
R
130
DS(ON)SEC2L
t
100
OFF2(MIN)
t
4.5
SS2
R
100
DIS2
V
0.96
FB3
V
−1
FB3(DEFAULT)
−2.5
∆V
/I
0.3
OUT3
LOAD
∆V
/V
0.1
OUT3
PVIN3
R
65
DS(ON)3H
R
50
DS(ON)3L
I
2.3
3
CL3
t
4
SS3
R
1
DIS3
Rev. Sp0 | Page 5 of 60
ADP50460008
Max
Unit
Test Conditions/Comments
5.3
V
+1.5
%
Default VID code
+2.5
%
−10°C ≤ T
≤ +85°C
J
%/A
I
= 100 mA to 600 mA
VOUT1
%/V
V
= 2.1 V to 4.5 V
VBATT
mΩ
I
= 100 mA
D
mΩ
I
= 100 mA
D
A
−10°C ≤ T
≤ +85°C
J
ns
ms
Default SFTTIM code
V
EN = low
Ω
I
= 30 mA, EN = low
D
ns
V
= 3.0 V
VBATT
3.65
V
+1.5
%
Default VID code
+2.5
%
−10°C ≤ T
≤ +85°C
J
%/A
I
= 100 mA to 600 mA
VOUT2
%/V
V
= 2.1 V to 4.5 V
PVIN2
mΩ
I
= 100 mA, V
D
mΩ
I
= 100 mA, V
D
A
−10°C ≤ T
≤ +85°C
J
mΩ
I
= 100 mA, V
D
mΩ
I
= 100 mA, V
D
ns
ms
Default SFTTIM code
Ω
1.26
V
+1
%
Default VID code
+2.5
%
−10°C ≤ T
≤ +85°C
J
%/A
I
= 100 mA to 1.4 A
VOUT3
%/V
V
= 2.1 V to 4.5 V
PVIN3
mΩ
I
= 100 mA
D
mΩ
I
= 100 mA
D
A
−10°C ≤ T
≤ +85°C
J
ms
Default SFTTIM code
kΩ
= 3.6 V
PVIN2
= 3.6 V
PVIN2
= 2.8 V
OUT2
= 2.8 V
OUT2
Need help?
Do you have a question about the ADP50460008 and is the answer not in the manual?