Saeco Group 500 Instruction And Maintenance Manual page 48

Table of Contents

Advertisement

English
The alarm E16- CAPACITY is a mere signal,
which does not block the machine, but does
indicate a progressive reduction of the water
delivery in the pump-solenoid valve circuit or an
inefficiency of the volume meter (small fan) or
the presence of limescale deposit on the
solenoid valves; this signal pre-announces an
imminent failure E04–PUMP.
Other signals that do not block the machine are
also foreseen and have the objective of advising
the user that the regeneration of descaler resins,
the grinders and filters is necessary.
The number of vends beyond which the
regeneration is deemed necessary is set in the
OPTIONS menu; the display messages
anticipated are:
- *
to indicate the error E16 CAPACITY
- a
to indicate the resin regeneration
- &
to indicate the filter replacement
- $
to indicate the grinder replacement
- #
to indicate the replacement of filters
and grinders
- %
to indicate resin regeneration and
grinder replacement
- W
to indicate resin regeneration and
filter replacement
- p
to indicate resin regeneration as well
as filter and grinder replacement.
If one of the above mentioned symbols is
displayed, by entering the SERVICE mode, the
message ALARM will appear followed by the
symbol for which maintenance is necessary.