- connect the tap to the distributor, using a rigid
copper or nylon pipe, suitable for foodstuffs
and adequate for the purpose of bearing the
water supply pressure. Should a flexible pipe
be used, it is necessary to assemble the
reinforcement bearing inside, which comes
supplied with the machine (fig.29);
fig.29
- the anticipated connection is a 3/8 gas
(Fig.30).
fig.30
6.3

Electric Mains connection

The distributor is designed to operate with
monophase 230 Volt voltage and is protected
by 10A and 16A fuses.
We suggest that you should check the following:
- the mains voltage of 230 V must not have a
difference of more than ± 6%;
- the power supply must be adequate to bear
the load of the machine;
- use a diversified protection system.
The machine must be earthed in observance
with operating safety norms.
For this reason, verify the system earth wire
connection to ascertain that it is efficient and in
compliance with national and European electric
safety standards.
If necessary, request the intervention of qualified
personnel for the verification of the plant.
- The distributor is equipped with a power
supply cable H05VV-F 3x1.5 mm
SCHUCO plug (fig.31).
fig.31