Setting #8 - Calibration Procedure
Figure 43
Adapter Dies and 32 mm Dies must be installed for calibration procedure as
directed. (See figure 42) Follow safe tooling installation instructions.
Figure 45
Press the motor on button to activate the hydraulic motor and then
crimp onto the small end of the mandrel until the green light no longer is
illuminated.
Motor On
Advance
!
KEEP HANDS CLEAR
25 | ©Danfoss ET5040 Crimp Machine Operator's Manual | 2022.10.
Figure 44
Install small end of mandrel as directed.
(See figure 43 & 44) (ET5040C-0019 tool)
Figure 46
Retract the crimp head until the large end mandrel loosely fits in. Rotate the
calibration tool and insert the large end into the crimp head and advance
the crimp tooling by depressing the advance button. (See figure 45).
Retract
Advance
!
KEEP HANDS CLEAR