TROUBLESHOOTING: GENERAL OVERVIEW - PAGE 2 of 2
CONDITION
Water Is On
Caution! Water on flooring can cause much damage! Until cause is determined (and
The Floor
repaired), following these procedures:
Use wet-dry vacuum (or mop & bucket) to remove standing water.
Use 'catch pans' for water to drain into. Swap out regularly until case has completely
drained.
TSP*: Check that the drain trap is free of debris.
TSP*: Check that the drain hose is correctly positioned over floor drain.
TSP*: Check store conditions. To prevent condensation in Type 1 environments,
maximum conditions are to be 55% humidity / 75 °Fahrenheit. For Type 2 environments,
maximum conditions are to be 60% humidity / 80 °Fahrenheit. See serial label (at case
rear near main power switch) for Type of your case.
TSP*: Check that overflow evaporator pan is plugged in and operating properly.
TSP*: Wicking material (shown below) may be dirty, worn, tattered or disintegrating.
Check if wicking material needs to be replaced with new.
Contact Structural Concepts Corporation for replacement wicking material (toll-free
number is listed on final page of operating manual).
If unable to stop water from draining on floor, Contact Structural Concepts Technical
Service. See telephone number on final page of operating manual.
*TSP = Trained Service Providers