nCounter Pro Analysis System User Manual

Safety Information (English)

The nCounter Analysis System may only be operated by appropriately trained, professional users.
NanoString recommends that all users read and understand this manual prior to attempting to
operate the system. Keep this manual with the instruments for easy access to instructions and safety
information. Failure to comply with the instructions in this manual may pose a dangerous risk to the
operator and void the manufacturer's warranty.
The Digital Analyzer is a Class 1 laser product. The instrument contains an internal Class 2 laser
barcode reader. Class 2 laser radiation exposure is possible while the Digital Analyzer cover is
opened. Do not stare into the barcode reader laser beam.
The Prep Station is a piece of electrical equipment for measurement, control, and laboratory
use. It contains high voltage and heater modules indicated by symbols on the deck. Avoid
contacting the heater module and electrodes. The instrument is equipped with a safety
interlock that will prevent voltage from being applied while the door of the instrument is open.
Do not use this device in close proximity to sources of strong electromagnetic radiation or
vibration, as it may interfere with proper operation.
Do not attempt to install, move, or disassemble the instrumentation.
Do not override the door sensors (pinch hazard exists).
Ensure that all consumables are properly inserted into the system prior to starting.
Operate the system using only NanoString nCounter reagents in accordance with their
indications for use.
Wear gloves while operating or performing user maintenance on the instrumentation.
Do not attempt to wash the Prep Station's electrodes or allow water or other solvents to come
into contact with the electrodes.
If it becomes necessary to wash either instrument's touchscreen, use a damp cloth to gently
wipe the surface. Do not use excessive water or other solvents, which may damage the screen.

Caution Symbols

BIOHAZARD:
the instrument may become contaminated with biohazardous materials. Please affix the proper warning labels to your Prep
Station if you use biohazardous inputs. Be careful not to touch this area without gloves or other personal protective equipment.
ELECTRICAL HAZARD
FOR RESEARCH USE ONLY. Not for use in diagnostic procedures.
8
Potential hazard from a biological source exists. If you choose to use biohazardous materials on your Prep Station,
CAUTION HOT SURFACE
SEV-00184-01