Chapter 7 Maintenance and Troubleshooting
Selection for Fault
F9.49
Protection Actions 3
Selection for Fault
F9.50
Protection Actions 4
Selection for Operating
F9.54
Frequency When Error
Occurs
Backup Frequency Upon
F9.55
Faults
Action Selection at
F9.59
Instantaneous Power
Failure
Voltage Check at
F9.60
Instantaneous Power
Voltage Check at
Instantaneous Power
F9.61
Recovery
Voltage Recovery
Check Time at
F9.62
Instantaneous Power
Failure
Adjusting KP when
Inverter does not stop at
F9.63
Instantaneous Power
Failure
Adjusting KI when
Inverter does not stop at
F9.64
Instantaneous Power
Failure
Protection upon Load
F9.65
Becoming 0
Detection Level of Load
F9.66
Becoming 0
Detection Time of Load
F9.67
Becoming 0
Units (Large Speed Deviation,Err42)
0: Coast to Stop
1: Stop (Stop Mode)
2: Continue to Run
0:Current Operating Frequency
1: Set Frequency
2: Frequency Upper Limit
3: Frequency Lower Limit
4: Backup Frequency Upon Faults
60.0%~100.0%
100.0%: Maximum Frequency(F0.10)
0:Invalid
1:PI Automatic Voltage Stabilization
2:Decelerate According to F4.08
80.0%~F9.61(Standard Bus Voltage)
F9.60~100.0%(Standard Bus Voltage)
0.00s~100.00s
1~100
1~100
0:Invalid
1:Valid
0.0~100.0%
0.0~60.0s
- 64 -
JT550 Series Inverter Manual
00000
00000
0
100.0%
0
90.0%
85.0%
0.50s
40
30
0
10.0%
1.0s