Veichi JT550 Series Manual page 21

Table of Contents

Advertisement

JT550 Series Inverter Manual
• Pr: the power of resistor.
• D: the braking frequency (percentage of the regenerative process to the whole working process)
Common
Applications
Selection of the
Breaking Frequency
The following table provides data for reference. User may select different resistance and power based on their
actual needs. However, the value of resistance must not be greater than the recommended value. The power
may be larger than the recommended value.
The braking resistor model depends on the generation power of the motor in the actual system and is also
related to the system's inertia, deceleration time and potential energy load. The higher a system's inertia is,
the shorter the deceleration time is. Frequent braking requires braking resisters of larger power and smaller
resistance.
Inverter Models
JT550-S2-0R4GB
JT550-S2-0R7GB
JT550-S2-1R5GB
JT550-S2-2R2GB
JT550-T3-0R7G/1R5PB
JT550-T3-1R5G/2R2PB
JT550-T3-2R2G/4R0PB
JT550-T3-4R0G/5R5PB
JT550-T3-5R5G/7R5PB
JT550-T3-7R5G/011PB
JT550-T3-011G/015PB
JT550-T3-015G/018PB
JT550-T3-018G/022PB
JT550-T3-022G/030PB
JT550-T3-030G/037P
JT550-T3-037G/045P
JT550-T3-045G/055P
JT550-T3-055G/075P
JT550-T3-075G/090P
JT550-T3-090G/110P
JT550-T3-110G/132P
JT550-T3-132G/160P
JT550-T3-160G/200P
JT550-T3-200G/220P
JT550-T3-220G/250P
JT550-T3-250G/280P
JT550-T3-280G/315P
JT550-T3-315G /355P
JT550-T3-355G /400P
JT550-T3-400G /450P
JT550-T3-450G
Uncoiling
Elevator
and Coiling
20%-30%
20%-30%
Recommended
Braking Resistor
Power
80W
80W
100W
100W
150W
150W
250W
300W
400W
500W
800W
1.0kW
1.3kW
1.5kW
2.5kW
3.7 kW
4.5 kW
5.5 kW
7.5 kW
4.5 kW×2
5.5 kW×2
6.5 kW×2
16 kW
20 kW
22 kW
12.5 kW×2
14 kW×2
16 kW×2
17 kW×2
14 kW×3
15 kW×3
- 21 -
Accidental
Centrifuge
Braking Load
50%-60%
5%
Recommended
Braking Resistor
Resistance
≥200Ω
≥150Ω
≥100Ω
≥70Ω
≥300Ω
≥220Ω
≥200Ω
≥130Ω
≥90Ω
≥65Ω
≥43Ω
≥32Ω
≥25Ω
≥22Ω
≥16Ω
≥12.6Ω
≥9.4Ω
≥9.4Ω
≥6.3Ω
≥9.4Ω×2
≥9.4Ω×2
≥6.3Ω×2
≥6.3Ω×2
≥2.5Ω
≥2.5Ω
≥2.5Ω×2
≥2.5Ω×2
≥2.5Ω×2
≥2.5Ω×2
≥2.5Ω×3
≥2.5Ω×3
Chapter 3 Electrical Installation
General
Occasions
10%
Braking Unit
Built-In
(Standard)
Built-In
(optional)
External
External