JT550 Series Inverter Manual
FC.17
Simple PLC retentive selection
PLC retentive upon power failure indicates that the inverter memorizes the PLC running moment and
running frequency before power failure and will continue to run from the memorized moment after it is
powered on again. If the unit's digit is set to 0, the inverter restarts the PLC process after it is powered on
again.
PLC retentive upon stop indicates that the inverter records the PLC running moment and running
frequency upon stop and will continue to run from the recorded moment after it starts up again. If the ten's
digit is 0, the inverter restarts the PLC process after it starts up again.
FC.17
Simple PLC retentive selection
0: Not retentive
1: Retentive
Unit position: Retentive at power down
Tens position: Retentive at stop
FC.18
Running time of simple PLC reference 0
Acceleration/deceleratio-n time of simple
FC.19
PLC reference 0
FC.20
Running time of simple PLC reference 1
Acceleration/deceleration time of simple
FC.21
PLC reference 1
FC.22
Running time of simple PLC reference 2
Acceleration/deceleration time of simple
FC.23
PLC reference 2
FC.24
Running time of simple PLC reference 3
Acceleration/deceleration time of simple
FC.25
PLC reference 3
FC.26
Running time of simple PLC reference 4
Range:00~11
Range:00~11
Range:
0.0s(h)~6553.5s(h)
Range:0~3
Range:
0.0s(h)~6553.5s(h)
Range:0~3
Range:
0.0s(h)~6553.5s(h)
Range:0~3
Range:
0.0s(h)~6553.5s(h)
Range:0~3
Range:
0.0s(h)~6553.5s(h)
- 115 -
Chapter 7 Maintenance and Troubleshooting
Default:00
Default:00
Default:0.0s(h)
Default:0
Default:0.0s(h)
Default:0
Default:0.0s(h)
Default:0
Default:0.0s(h)
Default:0
Default:0.0s(h)