JT550 Series Inverter Manual

3.6 Wiring Method

A typical wiring method of JT550 Series Inverter is shown below:
1.JT550-T3-045G/055P~132G/160P
The jumper bar across terminals P1 and (+) must be removed
when DC reactor is outside
Notes:
JT550-T3-037G/45P and the below series without DC reactor
JT550-T3-45G/55P and the above series with DC reactor
inside(optional)
Digital input terminals 1
Digital input terminals 2
Digital input terminals 3
Digital input terminals 4
Digital input terminals 5
Analog input
DC:0-10V
Analog input
DC:0-10V/0-20mA
Analog output
DC:0-10V/0-20mA
Analog output
DC:0-10V/0-20mA
Note:
1) Terminal ●: Major Loop Terminals , Terminal ○: Control Circuit Terminals.
2) The product models with "B" indicates the braking units.
3) Choose the braking resistors based on users' needs. Refer to Selection of Braking Unit and Braking
Resistor (P22-24).
4) Signal wires and power wires must be routed separately. If the control cables and power cables cross
together, it is best to make them crossed as 90 degrees. The analog signal line is best to use shielded twisted
pair; The power cable is best to use shielded three-core cable (its specifications are higher than the average
motor cable's) or to follow the user manual.
5) R is the standard relay, the relay E is optional.
MCCB
Single-phase AC
power input
220V 50/60Hz
MCCB
Three-phase AC
R
power input
S
380V 50/60Hz
T
Figure 3.2 Inverter's Major Circuit Wiring Diagram
X1
X2
X3
X4
X5(Pulse input Compatible)
COM
+10V
AI1
GND
AI2
GND
AO1
GND
AO2
GND
Figure 3.2 Inverter's Control Circuit Wiring Diagram
2.JT550-T3-045G/055P~710G need to connect with
braking unit and braking resistor outside
3.JT550-T3-0R7G/1R5PB~022G/030PB with braking
2
unit inside , just need to connect with braking resistor
1
Braking resistor
4.JT550-T3-037G/045P and the below series have no
DC
P1 terminal
reactor
Braking unit
5.JT550-T3-045G/055P and the below series have no
PB terminal
Braking resistor
3
Jumper
P1
P+
PB
N -
4
5
U
V
W
Main loop
Control loop
24V
PLC
EA
EB
EC
RA
RB
RC
AO1 AO2
AI2
V
I
Voltage/current switch
- 23 -
Chapter 3 Electrical Installation
M
Ground
Jumper
Relay output 1
Relay output 2
Y1
Open collector output
YCM
Y2/D0
Open collector output/High-speed pulse output
YCM
Jumper
Description :
COM
Main loop terminals
Control loop terminals
Shielded cables
Twisted pair cable

Hide quick links: