JT550 Series Inverter Manual
100CH
AI3 Voltage
100DH
Count Input
100EH
Length Input
100FH
Load Speed
-
Note:
Communication setting value is a relative value of 100 percentage. 10000 corresponds to 100.00%
while -10000 to -100.00%.
For the frequency dimension, this percentage is relative to the percentage of the max frequency
(F0.10).
2). Inverter Receiving Control Commands: (Write Only)
Command Address
3). Reading Inverter's Status: (Read Only)
Status Address
4)Digital Output Terminals Control: (Write Only)
Command Address
5) Analog Output AO1 Control: (Write Only)
Command Address
6). Analog Output AO2 Control: (Write Only)
Command Address
7) Pulse Output Control: (Write Only)
Command Address
-
0001:Forward Operation
0002:Reverse Operation
0003:Forward JOG
2000H
0004:Reverse JOG
0005:Coasting to Stop
0006:Decelerating to Stop
0007:Fault Reset
0001:Forward Operation
3000H
0002:Reverse Operation
0003:Halt
BIT0:Y1 Output Control
BIT1:Y2 Output Control
2001H
BIT2:RELAY1 Output Control
BIT3:RELAY2 Output Control
BIT4:FMR Output Control
2002H
0~7FFF represents 0%~100%
2003H
0~7FFF represents 0%~100%
2004H
0~7FFF represents 0%~100%
101CH
Input Pulse Frequency, Unit: 1Hz
101DH
Communication Setting Value
101EH
Actual Feedback Speed
101FH
Main Frequency X Display
1020H
Auxiliary Frequency Y Display
Command Function
Status Function
Command Contents
Command Contents
Command Contents
Command Contents
- 133 -
Chapter 7 Maintenance and Troubleshooting