JT550 Series Inverter Manual
Function
Parameter Name
Codes
Y2/DO Terminal Output
F3.00
Mode
Y1 Output Function
F3.01
Selection
Y2 Output Function
F3.02
Selection
Relay R Output Function
F3.03
Selection
Relay E Output
F3.04
Function Selection
F3.05
Reserved
Range of Settings
Group F3:Output Terminals
0:Pulse Output(DO)
1:Switch Signal Output(Y2)
0: No Output
1: Inverter Running
2: Output Errors (Stop)
3: Frequency Level Detection of FDT1
Output
4: Frequency Reached
5: Zero-Speed (No Output at Stop)
6: Motor Overload Pre-alarm
7: Inverter Overload Pre-alarm
8: Set count value reached
9: Designated count value reached
10: Length Reached
11: PLC Cycle Complete
12: Accumulated Operating Time Reached
13: Frequency Limited
14: Torque Limited
15: Ready for RUN
16: AI1
AI2
17: Frequency Upper Limit Reached
18: Frequency Lower Limit Reached(No
Output at Stop)
19: Under Voltage State Output
20: Communication Setting
21: Reserved
22: Reserved
23: Zero-Speed Operating 2 (Having Output
at Stop)
24: Accumulated Power-On Time Reached
25: Frequency Level Detection FDT2 Output
26: Frequency 1 Reached
27: Frequency 2 Reached
28: Current 1 Reached
29: Current 2 Reached
30: Timing Reached
31: AI1 Input Limit Exceeded
32: Load Becoming 0
33: Reverse Operation
34: Zero Current Status
35: Module Temperature Reached
36: Output Current Limit Exceeded
37: Frequency Lower Limit Reached
(Having Output at Stop)
38: Alarm Output
39: Motor Overheat Warning
40: Current Operating Time Reached
41:Analog Levels:ADT1
42:Analog Levels:ADT2
44:X1 Status
45:X2 Status
- 53 -
Chapter 7 Maintenance and Troubleshooting
Default
1
1
0
2
0
0
Property