Drain Connection - Bartscher RK401 LPWR Original Operation Manual

Hide thumbs Also See for RK401 LPWR:
Table of Contents

Advertisement

The required water pressure is 2–4 bar.
Water
pressure
If the water pressure exceeds the recommended value, it is required to install a
pressure controller between the water supply system and the water connection
of the appliance.
If the water pressure is below the recommended value, it is required to install
the booster pump at the water supply system connection.
The appliance is intended to be connected to a permanent water mains
connection. When using warm water, the water temperature may not exceed the
values of 50°C/122°F.
5.5

Drain Connection

EN
Fig. 16
16 / 32
MIN
bar
kPa
kg/cm
2
200
2,03
MAX
2
psi
bar
29
4
Water drain tube must consist of a sump
with free drain trap. Dimensions must be
suitable for the flow rate of the drain hose
delivered with the appliance. The drain
hose must be introduced into the sump
without pulling, bending, clenching, kinking
and any other obstacles.
Emptying the sump is executed by means
of gravitation, i.e. the drain must be located
below the bottom of the appliance.
If the drain is not below the bottom of the
appliance (as in a model with drain pump),
the maximum allowable drain height is 1
metre.
Check regularly if the drain works correctly
and for possible clogging.
Any other solutions must be consulted with
and approved of by the manufacturer
beforehand.
Installation Instructions
2
kPa
kg/cm
psi
400
4,07
58,01
110644