Installation Instructions
Fig. 13
5.3

Electrical Connection

The power cord should be laid in a way preventing anyone from threading on it
or tripping against it.
In normal operation or maintenance, the power cord cannot be stretched out nor
crushed.
Fig. 14
For the safety of the operator and the appliance, provide for proper grounding
pursuant to the safety regulations in force.
The appliance complies with the EN/IEC 61000-3-11 standard, on condition that
the system impedance Z
110644
To provide for stability, level the appliance
by screwing the feet in or out.
Correct levelling is indispensable in
ensuring optimum performance of the
appliance.
A universal main disconnecter must be used
that would disconnect all contacts, including
the zero distributor. The disconnected contact
must feature at least a 3 mm gap. The switch
must be activated by a thermo-magnetic
safety device or be coupled to fuses. The
fuses and the switch must be designed for the
power provided on the rating plate.
The main switch must be located in the power
line near the installation place. Only one
appliance may be permanently connected to
the main switch.
Verify if the technical specification of the
appliance (see the rating plate) corresponds
to the characteristics of the local electric
mains grid.
is lower or equals Z
sys
at the interface between the
max
EN
13 / 32