Automatic spray gun A15 eco
5.4

Connecting the automatic spray gun

Ä Chapter 5.3 'Connection scheme' on page 18).
See also (
WARNING!
Danger of injury due to improper connection!
When the fluid supply is pressurised, e.g. from pressure containers or with pumps, the range
of the fluid jet can increase by a multiple in case of atomiser air failure. This presents a hazard
to people and property.
Make sure that the fluid supply and the control air are interrupted if the atomiser air pres-
sure drops off quickly.
It is recommended to regulate the atomiser air pressure via a filter pressure reducer.
The connections for control and atomiser air are marked with letter abbreviations.
Fig. 4: Connecting the automatic spray gun
1.
Connect the control air to input "St" ( Fig. 4/3).
2.
Connect the atomiser air to input "Z" ( Fig. 4/2).
3.
Connect the material line to the connection ( Fig. 4/1) on the underside of the head section.