Automatic spray gun KAA 1300
6.5
Connecting the automatic spray gun
Fig. 4: Connecting the automatic spray gun
1.
Connect the control air to connection for control air ( Fig. 4/2).
The control air can only execute open and close functions. Dosing of the spray jet via
the control air is not possible.
2.
Connect the material line to the connection of the material supply ( Fig. 4/1).
If several airless spray guns are fed simultaneously from one high-pressure material
source, the closing of the material supply on one or to pull devices may cause repul-
sion changes at the remaining devices. The repulsion risk may be reduced by using
elastic material supply lines, e.g. high-pressure hoses instead of pipes.
Circulation operation
The circulation connection is recommended for example during the processing of settling
coating materials or materials for which the temperature must be kept constant.
3.
Remove lock screw ( Fig. 4/3) and closing plug.
4.
Screw in and tighten the double nipple or connecting bracket.
Item number: 200-0201