5.5

Connecting the automatic spray gun

Ä Chapter 5.4 'Connection scheme' on page 16.
See also
WARNING!
Danger of injury due to improper connection!
When the fluid supply is pressurised, e.g. from pressure containers or with pumps, the range
of the fluid jet can increase by a multiple in case of atomisation air failure. This presents a
hazard to people and property.
Make sure that the fluid supply and the control air are interrupted if the atomisation air
pressure drops off quickly.
It is recommended to regulate the atomisation air pressure via a filter pressure reducer.
The connections for control and atomisation air are marked with letter abbreviations.
Fig. 6: Connecting the automatic spray gun
1.
Connect the control air to input "St" ( Fig. 6/2).
2.
Connect the atomisation air to input "Z" ( Fig. 6/4).
3.
Connect the fluid line to ( Fig. 6/1 or 3).
4.
For models with circulation connection, connect the second fluid line to the fluid connection
( Fig. 6/5).
GB–18