Monitoring; Events - Ingeteam INGECON SUN 1Play TL M Installation And Usage Manual

Hide thumbs Also See for INGECON SUN 1Play TL M:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 45
Display control

12.6.1. Monitoring

This menu includes a series of screens which show the main variables being monitored. To move between the
different screens use the keys
See below for the structure and interpretation of the variables in this menu:
Pac
Inverter AC power, in watts.
Qac
Inverter AC reactive power, in reactive volt-amperes.
Sac
Inverter AC apparent power, in volt-amperes.
PhiCos
Cosine of Phi. Cosine of the phase shift angle between the voltage and current supplied by the
inverter.
Vac
AC voltage of the inverter, in volts.
Iac
AC current through the inverter, in amperes.
Fac
Frequency generated by the inverter, in hertz.
Pdc
Inverter DC power, in watts.
Pdc1
String 1 DC power, in watts.
Pdc2
String 2 DC power, in watts.
Riso
Insulation resistance of the PV array, in kiloohms.
Vdc1
DC input voltage of string 1.
Vdc2
DC input voltage of string 2.
Idc1
DC input current of string 1.
Idc2
DC input current of string 2.
Total
Energy
Total energy fed through the inverter throughout its useful life.
Time
Total time that the inverter has been feeding the grid.
Connections Total number of network connections.
Partial
Energy
Partial energy fed by the inverter.
Time
Partial time that the inverter has been connected to the grid.
Connections Partial number of network connections.

12.6.2. Events

This menu shows the events occurring in the inverter.
Alarms
The alarms indicate current events in the inverter that lead to its shut-down. In section "17.1. Alarms. LED
messages" you can consult the list of alarms and their solution.
Warnings
The warnings are events that do not lead to the shut-down of the inverter but do need maintenance action. In
section "17.2. Warnings" you can consult the list of warnings and their solution.
Reasons for shutdown
Log file that indicates the alarms that have triggered the inverter shutdown, indicating the date and time of the
shutdown.
Delete reasons for shutdown
This option resets the Reasons for shutdown log file.