12.2. Display

The main display shows different inverter data:
A.
Current date, YYYY-MM-DD.
B.
Power reduction percentage of and reason for this reduction*.
C.
Current time, hh:mm.
D.
Voltage and power of the PV array. Both pieces of data are viewed of forming alternately.
E.
Power, voltage and current fed to the public grid.
F.
Watt meter for instantaneous self-consumption. This symbol is only shown if the inverter is configured to
work in self-consumption mode. If it flashes, this is due to a communication failure with the watt meter.
Pressing the key
takes you to the main menu. Pressing the key
displays the energy graph for the last 24 days.
* The reasons for power reduction are as follows:
T: Temperature. The inverter is limiting the power due to internal overheating.
C: Communications. The inverter is limiting the power after having received a reduction setpoint through
communications.
F: Grid frequency. The inverter is limiting the power due to the grid frequency variation.
V: Grid voltage. The inverter is limiting the power due to the grid voltage variation.
Q: Reactive priority. The inverter is limiting the power due to the injection of reactive power.
A: Configuration. The inverter is configured to limit its power.
R: Initial connection ramp. The inverter is limiting the power after a reconnection to the grid.
S: Self-consumption mode. The inverter is limiting the power due to functioning in self-consumption
mode.
M: Reserved mode.
72
A
B
06/05/2014
06/05/2014
D
C
10:17
10:17
F
E
displays the daily power graph. Pressing
ABE2011IQM01_ - Installation and usage manual