KEB COMBIVERT S4 Instruction Manual page 45

Hide thumbs Also See for COMBIVERT S4:
Table of Contents

Advertisement

Possible Cause
- Input voltage too low or unstable
- Voltage losses due to incorrect cabling
- Input voltage too high
- Retarding torque too high
- Short-circuit or ground fault at the output
- middle torque too large
- wrong cabling
- PTC - triggering
- PTC - line defective
- Heat dissipation too low
- Ambient temperature too high
- Motor is overloaded
- External error presetting
! Only if parameter CP.15 = 0 !
- Short-circuit of reference voltage of the resolver
12. Error Diagnosis
Fault Remedy
- Check voltage suppply
- Check input line
- Check voltage suppply
- Connect braking resistor
- Determine exact cause and remove, next re-start
- Reduce torque
- Control cabling from the motor to the encoder system
- Let motor cool down
- Check PTC - line
- Observe correct installation
- See also ambient conditions page E 7
- Discharge motor
- Reduce torque limit (Parameter CP.9)
- Remove external error and actuate RESET
- Check resolver line
- Fault correction only ex works!
- Fault correction only ex works!
- Fault correction only ex works!
ANTRIEBSTECHNIK