Parameter
Parameter Name
number
CP.0
Password input
CP.1
Actual speed display
CP.2
Status display
*
CP.3
Apparent motor current
*
CP.4
Max. apparent motor current
*
CP.5
Current Torque
CP.6
Setpoint speed display
CP.7
Acceleration time
CP.8
Deceleration time
CP.9
Torque limit
CP.10
Max. setpoint speed
CP.11
Jogging speed
CP.12
P-factor speed controller
CP.13
I-factor speed controller
CP.14
Line number incremental encoder simulation
CP.15
Behaviour at external fault
CP.16
Offset REF 1
CP.17
Zero point hysteresis REF 1
CP.18
Function output A1
CP.19
Amplification output A1
CP.20
Amplification output A2
CP.21
Switching condition output D1
CP.22
Switching condition output D2
CP.23
Torque level output D1
CP.24
Speed level output D2
*
With the actual values displayed, from the normal machine dispersion and temperature drifts,
tolerances must be taken into account. (about ± 10% in relation to the nominal value)
E 26
CP-Parameter
(CP.0 ... CP.24)
Read-Only Parameters
can only be read they
cannot be changed.
(CP.1 ...CP.6, CP.14)
NO-ENTER-Parameters
are programmable parameters, a
change is accepted and stored
immediately.
(CP.7 ... CP.13, CP.16, CP.17,
CP.19, CP.20, CP.23, CP.24)
Setting Range
0...9999
0...320 s
0...320 s
0...5 x M
0...9999
0...9999
0...65535
0...65535
-100%...+100 %
0...10 %
-20...+20
-20...+20
0...50 Nm
0...16000 U/min
Programmable Parameters
can be changed (CP.0,
CP.7 ... CP.13, CP.15 ... CP.24)
ENTER-Parameters
are programmable parameters a
change must be confirmed with
the ENTER-key before it is
accepted and stored.
(CP.0, CP.15, CP.18, CP.21, CP.22)
Resolution
1
0,5 U/min
0,1 A
0,1 A
0,1 Nm
0,5 U/min
0,01 s
0,01 s
0,1 Nm
N
0,5 U/min
0,5 U/min
1
1
-
-
0...6
1
0,1 %
0,1 %
0...6
1
0,01
0,01
0...20
1
0...20
1
0,1 Nm
0,5 U/min
Factory Setting
0,05 s
0,05 s
3 x M
N
Rated speed
100 U/min
Motor-type dependent
Motor-type dependent
512 / 2048
0
0 %
0 %
2
^
3 x M
= +10 V
Rated
^
+/–n
= +/–10 V
Rated
20
18
0,5 x M
Rated
0,5 x n
Rated