8. Parameter Description
Switching Condition
Output D2
Switching Conditions
Torque Level Output D1
Speed Level Output D2
E 36
Defines the switching condition of
digital output D2.
! Refer to table below !
Digital output D1 and D2
Value Switching condition
0
always active
1
always active
2
system switched on; no abnormal operating condition
3
ready for operation and modulation enabled
4
abnormal operating condition / Fault (CP.2 = A.xxx or E.xxx)
5
inverter blocking after fault (E.xxx)
6
prewarning level electr. protective motor relay (OH.2) exceeded
7
after triggering of motor PTC-contact
8
prewarning level OH.2 or dOH exceeded
9
current controller in limitation
10
speed controller in limitation
11
any controller in limitation
12
drive in acceleration phase
13
drive in deceleration phase
14
drive runs with constant speed
15
drive runs with constant speed except speed 0
16
clockwise rotation – not at noP, LS, abnormal stopping or fault
17
anti-clockwise rotation - not at noP, LS, abnormal stopping or fault
Only digital output D1
18
actual speed > 0,1 x rated speed
19
apparent current > rated current
20
torque > torque level CP.23
Only digital output D2
18
actual speed > speed level CP.24
19
apparent current > rated current
20
torque > rated torque
Defines the torque level of digital
output D1.
Defines the speed level of digital
output D2.
Setting range:
Resolution:
Factory setting:
Remarks:
ENTER–Parameter
Customer setting:
Setting range:
Resolution:
Factory setting:
Customer setting:
Setting range:
0...16000 U/min
Resolution:
Factory setting:
Customer setting:
0...20
1
18
0...50 Nm
0,1 Nm
0,5 x M
Rated
Nm
0,5 U/min
0,5 x n
Rated
U/min