KEB COMBIVERT S4 Instruction Manual page 29

Hide thumbs Also See for COMBIVERT S4:
Table of Contents

Advertisement

Status Display
Apparent Motor Current
Apparent Motor Current
Peak Value
8. Parameter Description
The status display indicates the current operating condition of the servo controller.
Possible indications and their meaning are listed in the following:
no Operation – Control release (terminal X2.1)not activated
Forward
acceleration
Forward
deceleration
Reverse
acceleration
Reverse
deceleration
Forward
constant
Reverse
constant
Prohibited
A
b
rotation
n
forward
o
r
m
a
l
Prohibited
rotation
S
reverse
t
o
p
p
i
External
n
fault
g
Indication of the current apparent motor current in ampere.
Resolution: 0,1 A
Indication of the maximum apparent motor current measured during operation, in
ampere.
Resolution: 0,1 A
– Modulation switched off
– Output voltage= 0V/drive uncontrolled
– Drive accelerates with forward direction of
rotation
– Drive decelerates with forward direction of
rotation
– Drive accelerates with reverse direction of
rotation
– Drive decelerates with reverse direction of
rotation
– Drive runs with constant speed and forward
direction of rotation
– Drive runs with constant speed and revers
direction of rotation
– Rotation release at terminal X2.3 is missing:
Drive does not start with positive reference
value or decelerates to standstill(speed zero
is maintained). After release of rotation the
drive starts again automatically.
– Rotation release at terminal X2.4 is missing:
Drive does not start with negative reference
value or decelerates to standstill (speed zero
is maintained). After release of rotation the
dirve starts again automatically.
– The signal for an external fault is applied to
terminal X2.7. The response of the drive to
external faults is adjusted with parameter
CP.15
– Error - Messages see Page E 44
"Error Diagnoses"