10. Accessories
10.2
Radio
Interference
Suppression Filter

10.2.1 Technical Data

10.2.2 Connection

Connection 1-phase
Connection 3-phase

10.2.3 Dimensions

12.U4.00E-CM00
E 40
The servo controller KEB COMBIVERT S4 can be supplied ex factory with internal
radio interference suppression filter. Base filters are available for the unit sizes 03,
05 and 10. Unit size 10 can only be delivered with an external filter.
Servo controller
03 (D-Housing)
1)
07.U4.00D-B600
05 (D-Housing)
1)
07.U4.00D-B600
10 (D-Housing)
1)
10.U4.00D-BM00
12 (E-Housing)
12.U4.00E-CM00
1)
Dimensions Servo controller with base filter see Page E 17
2)
only for 1-phase Servo controller

Radio Interference Suppression Filter

L
N
PE
Radio Interference Suppression Filter
L1
L2
L3
PE
200
Part.No.:
I
[A]
N
Filter-kit
Rated current Rated voltage
2)
12
2)
12
8
22
Servo Controller
L1
L2
PE
Servo Controller
L1
L2
L3
PE
U
[V]
N
250
250
500
500
U
M
V
3 ~
W
PE
U
M
V
3 ~
W
PE
Ø 6
40
80

Hide quick links: