Behaviour at External Fault
Offset REF 1
8. Parameter Description
This parameter determines the
response of the drive to an external
fault.
Value Response of Drive
0
Error message: E.EF
! To restart eliminate the fault and make a Reset !
1
Status message: A.EF
attaining speed 0.
! To restart eliminate the fault and make a Reset !
2
Status message: A.EF
! To restart eliminate the fault and make a Reset !
3
Status message: A.EF
! Automatic restart when fault condition no longer exists !
4
Status message: A.EF
attaining speed 0.
! Automatic restart when fault condition no longer exists !
5
Status message: A.EF
! Automatic restart when fault condition no longer exists !
6
Status message: none
! Fault is ignored !
Permits the shifting of the setpoint-speed characteristic.
n
max
2)
1)
"forward"
3)
-10 V
+10 V
n
max
"reverse"
Examples:
Characteristic 1: CP.16 = 0% (standard setting)
0V = 0 U/min
Rotation "forward": n
is attained at +10V
max
Rotation "reverse": n
is attained at -10 V
max
Characteristic 2: CP.16 = +40%
0V = 40 % of n
"forward"
max
Rotation "forward": n
is attained at 60% of +10V
max
Rotation "reverse": maximal 60% of n
Characteristic 3: CP.16 = –70%
0V = 70 % of n
"reverse"
max
Rotation "forward": maximal 30% of n
Rotation "reverse": n
is attained at 30% of -10V
max
Setting range:
Resolution:
Factory setting:
Remarks:
Customer setting:
→
Immediate disconnection of inverter!
→
→
Fast stop
Disconnection of inverter after
→
→
Fast stop
Holding torque at speed 0.
→
Immediate disconnection of inverter.
→
→
Fast stop
Disconnection of inverter after
→
→
Fast stop
Holding torque at speed 0.
→
No effect on the drive.
Adjustment of parameter
CP.7 and CP.8 must be
observed!
Setting range:
Resolution:
Faxtory setting:
Customer setting:
possible
max
possible
max
ANTRIEBSTECHNIK
0...6
1
0
ENTER-Parameter
-100...+100 %
0,1 %
0 %
%
E 33