Repair Procedures - Daikin RXTA30B2V1B Service Manual

R32 optimized heating 4 split
Hide thumbs Also See for RXTA30B2V1B:
Table of Contents

Advertisement

4
|
Components

4.23.2 Repair procedures

To remove the wifi control PCB
Service manual
206
4 Measure the output voltage between between the pins 4‑5 on the connector
S801 on the indoor unit main PCB.
Result: The measured voltage MUST be 10~16 V DC.
Is the output voltage on the indoor unit
main PCB correct?
Yes
No
5 As there are no further check procedures for this component, perform a check
of the indoor unit main PCB to check if the wifi control PCB needs to be
replaced. See
"4.10.1 Checking
After complete check of the indoor unit
main PCB, is the problem solved?
Yes
No
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Disconnect the connector from the wifi control PCB.
2 Carefully click the complete wifi control PCB assembly out of the indoor unit.
A
A Indoor unit FTXTA-B
a Wifi control PCB assembly
Action
Replace the wifi control PCB wiring
harness, see
"4.23.2 Repair
4
procedures" [
 206].
Perform a check of the indoor unit main
PCB, see
"4.10.1 Checking
4
procedures" [
 97].
4
procedures" [
 97].
Action
No further actions required.
Replace the wifi control PCB, see
"4.23.2 Repair
procedures" [
"4.17 Plate
a
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
4
 206].
4
work" [
 144].
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents