Daikin RXTA30B2V1B Service Manual page 54

R32 optimized heating 4 split
Hide thumbs Also See for RXTA30B2V1B:
Table of Contents

Advertisement

4
|
Components
To remove the 4-way valve body
Service manual
54
Prerequisite: If needed, remove any parts to create more space for the removal of
the 4‑way valve coil.
1 Remove the screw and remove the 4‑way valve coil from the 4‑way valve
body.
a Screw
b 4‑way valve coil
c 4‑way valve body
2 Cut all tie straps that fix the 4‑way valve coil harness.
3 Unplug the 4-way valve connector from the appropriate PCB.
4 To install the 4‑way valve coil, see
Prerequisite: Recuperate the refrigerant from the refrigerant circuit, see
"5.2.2 Repair
procedures" [
1 Remove the 4‑way valve coil from the 4‑way valve body, see
4
procedures" [
 53].
2 Remove and keep the putty (if installed) and the insulation (if installed) for re-
use.
3 Supply nitrogen to the refrigerant circuit. The nitrogen pressure MUST NOT
exceed 0.02 MPa.
4 Wrap a wet rag around the components near the 4‑way valve pipes. Heat the
brazing points of the 4‑way valve pipes using an oxygen acetylene torch and
remove the 4‑way valve pipes from the refrigerant pipes using pliers.
a
b
c
"4.1.2 Repair
4
 216].
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
4
procedures" [
 53].
"4.1.2  Repair
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents