4
|
Components
To install the swing flap motor
Service manual
176
FTXTM30R
1 Install the coupling piece on the swing flap motor.
2 Install the swing flap motor in the correct location on the indoor unit.
a
a Swing flap
b Screw (swing flap motor fixation)
c Swing flap motor
d Coupling piece
3 Install and tighten the screw to fix the swing flap motor.
4 Install the swing flap.
5 Install the swing raster motor, see
6 Install the switch box, see
Is the problem solved?
Yes
No
FTXTM40R
1 Connect the wiring harness to the swing flap motor.
2 Install the swing flap motor on the correct location on the indoor unit. Make
sure the swing flap motor shaft is correctly inserted in the link.
d
b
c
"4.21.2 Repair
procedures" [
4
"4.17 Plate
work" [
 144].
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
RXTM-R+RXTP-R+ARXTP-R+RXTA-B+FTXTA30B2V1B(W)
(B)+FTXTM30+40R2V1B+FTXTP25+35M5V1B+ATXTP25+35M5V1B
4
 186].
R32 Optimized Heating 4 Split
ESIE21-12A – 2022.02