  • Page 1 Operation manual Daikin room air conditioner FTXTM30R2V1B Operation manual FTXTM30S2V1B English Daikin room air conditioner FTXTM40S2V1B...
  • Page 2: Table Of Contents

    ▪ Detailed step-by-step instructions and background information Flash Streamer and Fireplace logic operation......10 for basic and advanced usage 5.9.1 Flash Streamer (air cleaning) operation...... 10 ▪ Format: Digital files on https://www.daikin.eu. Use the search 5.9.2 Fireplace logic operation..........10 function to find your model.
  • Page 3: Instructions For Safe Operation

    CAUTION (e.g. open flames, an operating gas NEVER expose little children, plants or appliance, or an operating electric animals directly to the airflow. FTXTM-R, FTXTM-S Operation manual Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 4: About The System

    When operation is started dealer. using this button, the following settings are used: ▪ Operation mode = Automatic ▪ Temperature setting = 25°C ▪ Airflow rate = Automatic Operation manual FTXTM-R, FTXTM-S Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 5: About The User Interface

    Clock and indoor unit display brightness button OFF/ON timer operation buttons Weekly timer operation buttons Flash Streamer and Fireplace logic operation button Econo and Outdoor unit quiet operation button Mode button Powerful button FTXTM-R, FTXTM-S Operation manual Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 6: To Set The Clock

    Operation range Use the system in the following temperature and humidity ranges for safe and effective operation. Operation manual FTXTM-R, FTXTM-S Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 7: To Start/Stop Operation Mode And To Set The Temperature

    Note: The display automatically returns to the home screen after (lower outdoor ambient temperature = higher increase 60 seconds. To return to the default screen sooner, press of target indoor temperature setpoint). FTXTM-R, FTXTM-S Operation manual Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 8: Airflow Rate

    5.5.1 To adjust vertical airflow direction with people. If no movement is detected for 20 minutes, the system switches to energy saving operation: 1 Press Operation manual FTXTM-R, FTXTM-S Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 9: To Start/Stop Comfort And Intelligent Eye Operation

    Note: Powerful operation can be set only when the unit is running. If you press or if you change operation mode, operation will be cancelled; disappears from the LCD. FTXTM-R, FTXTM-S Operation manual Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 10: Flash Streamer And Fireplace Logic Operation

    You can also use OFF Result: and the set time are displayed on the LCD. The timer timer and ON timer in combination. lamp lights up. Operation manual FTXTM-R, FTXTM-S Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 11: Hour Countdown Off/On Timer Setting

    LCD. and check for a receiving tone when setting the Weekly timer The Daikin eye lights orange. The time displayed on the LCD will operation. automatically count down by 1 hour for every hour that passes.
  • Page 12: To Copy Reservations

    LCD. 10 Repeat the previous procedure to set another reservation or Result: disappears from the LCD and the timer lamp goes press to complete the setting. off. Operation manual FTXTM-R, FTXTM-S Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 13: To Delete Reservations

    3 Check the operation and timer LEDs on the indoor unit display. Do NOT use near: ▪ Medical equipment. E.g. persons using cardiac pacemakers or defibrillators. This product cause electromagnetic interference. FTXTM-R, FTXTM-S Operation manual Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 14 4  14]. 2 Change to the SP menu  by pressing once or repeatedly. 5 Press to exit the menu. Result: The display will return to the default screen. Operation manual FTXTM-R, FTXTM-S Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 15: Maintenance And Service

    If damaged, the unit may fall and result in injury. CAUTION Do NOT touch the heat exchanger fins. These fins are sharp and could result in cutting injuries. FTXTM-R, FTXTM-S Operation manual Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 16: To Clean The Indoor Unit And Wireless Remote Control

    2 Remove the front panel by sliding it to the left or the right and pulling it toward you. Result: The front panel shaft on 1 side will be disconnected. Operation manual FTXTM-R, FTXTM-S Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 17: To Clean The Titanium Apatite Deodorising Filter And The Silver Particle Filter (Ag-Ion Filter)

    This results in poor performance. 4 After washing, shake off remaining water and dry the filter in the shade. Do NOT wring out the filter when removing water. FTXTM-R, FTXTM-S Operation manual Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 18: Winter Season

    (with manufacturing number if possible) and the installation date (possibly listed on the warranty card). Operation manual FTXTM-R, FTXTM-S Daikin room air conditioner 3P717028-3B – 2023.03...
  • Page 20 3P717028-3B 2023.03 Verantwortung für Energie und Umwelt...